Chapter 5: Operation of CLI Management
724-746-5500 | blackbox.com
171
Example:
LPB4008A(alarm-events)# set all 1-3
set email
Syntax: set email <range>
Description: Enable the events email.
Argument: <range>: set the range of email, syntax 1, 5-7
Possible value: <range>: 1~24
Example:
LPB4008A(alarm-events)# set email 1-3
set trap
Syntax: set trap <range>
Description: Enable the events trap.
Argument: <range>: set the range of trap, syntax 1, 5-7
Possible value: <range>: 1~24
Example:
LPB4008A(alarm-events)# set trap 1-3
Show
Syntax: show
Description: Display the alarm event configuration.
Argument: None.
Possible value: None.
Example:
LPB4008A(alarm-events)# show
Events Email Trap
-----------------------------------------
1 Cold Start v
2 Warm Start v
3 Link Down v
4 Link Up v
5 Authentication Failure v
6 Login
7 Logout
8 Module Inserted
9 Module Removed
10 Dual Media Swapped
11 Looping Detected
12 STP Disabled
13 STP Enabled
14 STP Topology Changed
15 LACP Disabled