40
1.
Press Order.
The range is limited by the maximum output frequency of the instrument and
current fundamental waveform frequency.
Range: 2 to maximum output frequency of the instrument ÷ current fundamental
waveform frequency
The maximum is 10.
2.
Use the numeric keyboard or knob to input the desired value.
When the knob is used, the changes to the “Harm Order” will be immediate.
When the numeric keypad is used, after entering the value, the Accept softkey
should be pressed to enter the value.
To Select the Harmonic Amplitude
1.
Press Order to select the sequence number of the harmonic to be set.Press Harmonic Ampl
to set the amplitude of the harmonic selected. The units available are Vpp, mVpp and dBc.
2.
This process should be repeated for each harmonic.
To Select the Harmonic Phase
After entering the harmonic setting menu, press Harmonic Phase to set the phase of each
harmonic.
1.
Press Order to select the sequence number of the harmonic to be set.
2.
Press Harmonic Phase to set the phase of the harmonic selected. Use the arrow keys and
knob to change the value. Alternatively, use the numeric keyboard to input the phase value
and then select the unit ° (degrees).
This process should be repeated for each harmonic.
3.4
Configure Modulation Output
Use the Mod key to generate modulated waveforms. The generator can generate AM, FM, ASK,
FSK, PSK, PM, PWM and DSB-AM modulated waveforms. Modulating parameters vary with the
types of the modulation.
Modulation Type Parameter Settings
www.
.com
1.800.561.8187