SPP-R200II Command Manual
Rev. 1.00
BIXOLON
- 31 -
- When set to Track 1 Read mode
Normal mode
02H 41H 31H 31H 1CH Max DATA 76 characters (1Track data) 03H 0DH 0AH
1byte sentinel character mode
02H 41H 31H 31H 1CH (Header) 25H (STX) Max DATA 76 characters (1Track data) 3FH (ETX) 03H 0DH 0AH (End)
Multi byte sentinel characters mode
START characters
(Max 10 byte)
Max DATA 76 characters (1Track data)
END characters
(Max 10 byte)
0DH 0AH
- When set to Track 2 Read mode
Normal mode
02H 42H 31H 31H 1CH Max DATA 37 characters (2Track data) 03H 0DH 0AH
1byte sentinel character mode
02H 42H 31H 31H 1CH (Header)
3BH
(STX)
Max DATA 37 characters
(2Track data)
3FH
(ETX)
03H 0DH 0AH
(End)
Multi byte sentinel characters mode
START characters
(Max 10 byte)
Max DATA 37 characters
(2Track data)
END characters
(Max 10 byte)
0DH 0AH
- When set to Track 3 Read mode
Normal mode
02H 44H 31H 31H 1CH
Max DATA104 characters
(3Track data)
03H 0DH 0AH
1byte sentinel character mode
02H 44H 31H 31H 1CH (Header)
3BH
(STX)
Max DATA 104 characters
(3Track data)
3FH
(ETX)
03H 0DH 0AH
(End)
Multi byte sentinel characters mode
START characters
(Max 10 byte)
Max DATA 104 characters
(3Track data)
END characters
(Max 10 byte)
0DH 0AH