SPP-R200II Command Manual
Rev. 1.00
BIXOLON
- 99 -
<Function 12> GS ( E pL pH fn a (fn=12)
Code:
ASCII
GS
(
E
pL
pH
fn
a
Hex
1D
28
45
pL
pH
fn
a
Decimal
29
40
69
pL
pH
fn
a
Range:
(pL + pH x 256) = 2 (pL=2, pH=0)
fn=12, 1 ≤ a ≤ 4
Default:
None
Description:
■
This command transmits the communication conditions of the serial interface according to a as follows:
a
Communication Condition
1
Baud rate
2
Parity
3
Flow control
4
Data length
■
The data format to be transmitted is as follows:
Hexadecimal
Decimal
Amount of Data
Header
37H
55
1 byte
Identifier
33H
39
1 byte
Communication condition(a)
31H - 34H
49 - 52
1 byte
Separator
1FH
31
1 byte
Setting value
30H - 39H
48 - 57
1 - 6 bytes
NUL
00H
0
1 byte
Communication condition is define by “a” and setting value defined as shown in the following.