<Function 48> GS ( L pL pH m fn (fn=0, 48)
Code:
ASCII
GS
(
L
pL
pH
m
fn
Hex
1D
28
4C
pL
pH
m
fn
Decimal
29
40
76
pL
pH
m
fn
Range:
(pL + pH x 256) = 2 (pL=2, pH=0)
m=48, fn=0, 48
Default:
None
Description:
■
Transmits the total capacity of the NV bit-image memory (number of bytes in the memory area).
Hexadecimal
Decimal
Amount of Data
Header
37H
55
1 byte
Flag
30H
48
1 byte
Data
30H - 39H
48 - 57
1 - 8 bytes
NUL
00H
0
1 byte
■
The total capacity data is converted to character codes corresponding to decimal data, then transmitted from the
MSB.
Remarks:
Differences:
■
This command is available in both standard and page modes.