SPP-R200II Command Manual
Rev. 1.00
BIXOLON
- 105 -
<Function 51> GS ( L pL pH m fn (fn=3, 51)
Code:
ASCII
GS
(
L
pL
pH
m
fn
Hex
1D
28
4C
pL
pH
m
fn
Decimal
29
40
76
pL
pH
m
fn
Range:
(pL + pH x 256) = 2 (pL=2, pH=0)
m=48, fn=3, 51
Default:
None
Description:
▪ Transmits the number of bytes of remaining memory (unused area) in the NV user memory.
Hexadecimal
Decimal
Amount of Data
Header
37H
55
1 byte
Flag
31H
49
1 byte
Data
30H
– 39H
48 - 57
1 - 8 bytes
NUL
00H
0
1 byte
■
The number of bytes of remaining memory is converted to character codes corresponding to decimal data, then
transmitted from the MSB.
■
The data length is variable.
Remarks:
Differences:
None