48
40016512
49
11/2017
2.2 Connecting the appliance
The technical specifications of your radiator are shown on its nameplate.
Please note these down before installing it and before requesting any after-sales assistance.
When connecting the appliance to the mains, you must observe:
• the voltage indicated on the nameplate;
• conventional colour coding:
– blue or grey: neutral
– brown: live
– black: pilot wire
CONNECTING PRINCIPLE WITH PILOT WIRE:
Your appliance is equipped with a pilot wire for connection to a pilot wire programming base unit
(not supplied with the appliance).
CONNECTING PRINCIPLE WITHOUT PILOT WIRE:
If the pilot wire is not connected, it must be insulated for safety reasons. Under no circumstances
must it be connected to earth.
N (blue or grey)
Neutral
Live
Pilot wire (base unit)
Live
Neutral
L (brown)
Pilot wire (black)
Pilot wire (black)
L (brown)
N (blue or grey)
3. Using your dual-energy towel radiator
IMPORTANT
This appliance has been designed to be used ei-
ther in central heating mode or electric mode. Each application
requires special, detailed procedures to be followed. Inappro-
priate use may damage the resistance as a result of excessive
fluid temperatures, particularly in the event of simultaneous use
in electric and central heating modes.
Any inappropriate use will render the contractual guarantee null
and void.
3.1 Use as central heating
Ensure that the control unit is off.
The supply valve must be open to let water from the central heating system circulate.
3.2 Use as electrical heating
A.
When using the dual-energy, towel-drying radiator in "electric mode", close the supply valve
only and
NEVER CLOSE THE HEATING UNIT’S OUTLET
since this enables the fluid to expand
towards the installation.
B.
Ensure that the appliance is sufficiently full by opening the bleed tap at the top. Close it again
if there is a steady flow of water. A sponge and small container should be used for this operation.
If the pressure is inadequate for bleeding the heating unit:
• fill the central heating system with water up to the level indicated on your gauge,
• contact your heating specialist,
• inform the operating company (where heating is collective).
C.
To start the appliance, follow the same procedure as for an electric towel-dryer.
If the central heating system is equipped with a circulation pump which is independent of the
boiler,
it must in all circumstances be turned off
(risk of siphoning the heating unit in the event
that connections are not perfectly watertight).
IP: protection level of your appliance against the
ingress of solid foreign bodies and water spray
Voltage and power required for installation
Appliance reference number
Class II: double insulated
OF: serial number
Manufacturer code
IP XX
XXX–XXX–XXX–XX
230V ~ XXXXW
OF: XXXXXXXXXX XXXXXX
N CONSTRUCTEUR XXXXXX
NOTE:
Your appliance is equipped with an integrated electronic control system so we cannot accept
any liability should the appliance be used with pilot wire programming base units that function by
disconnecting the supply voltage (refer to the instructions supplied with your control unit).
CAUTION
Closing it may cause excessive pressure to build up with consequential damage to the
heating unit.
IMPORTANT:
The appliance should only be turned on when properly filled with water
(failure to