5
Sensor Function
RegloBeam 2
Function
Description
Factory Settings in
bold
with *
Mounting Height
A
Hight
Value
2.0
– 2.5 m
2.5 – 3.0 m
’
3.0 – 4.0 m
4.0 – 5.0 m
*
5.0 – 6.0 m
'
5.0 –
7.0 m
i
Ensure proper mounting height
is programmed for optimum
sensor performance
i
For
people/vehicle separation
use mounting height
3 m
and up
i
For wide field use mounting height
under 4 m
After mounting height is set, most typical
applications require no further program-
ming.
Output #1
Configuration
Green LED
Yellow & green
wires
?
In
Out
B
*
Vehicles forward
Vehicles backward
Vehicles both directions
People forward
People backward
People both directions
People & vehicles forward
People & vehicles backward
People & vehicles both directions
Output #2
Configuration
Red LED
Pink & grey wires
?
In
Out
C
Vehicles forward
Vehicles backward
Vehicles both directions
*
People forward
People backward
People both directions
People & vehicles forward
People & vehicles backward
People & vehicles both directions
Output #1
Field size/
sensitivity
D
X-Small field/least sensitive
Small field/less sensitive
Medium field/normal sensitivity
*
Large field/very sensitive
X-Large field/most sensitive
Output #2
Field size/
sensitivity
E
X-Small field/least sensitive
Small field/less sensitive
Medium field/normal sensitivity
*
Large field/very sensitive
X-Large field/most sensitive
* Factory settings
To activate
this output,
press
F
followed by
..
5.2
Programming Sensor Functions by Remote Control