background image

6

Sensor Function

RegloBeam 2
Function

Description

Factory Settings in 

bold

 with *

Output #1  

Hold Time

F

  

1

0.2 sec

0.5 sec

1.0 sec

 

*

2.0 sec

5.0 sec

Pulse on exit

Output steadily on (for testing purposes only)

Output steadily off

Output #2  
Hold Time

F

  

2

0.2 sec

0.5 sec

1.0 sec

2.0 sec

5.0 sec

Pulse on exit

Output steadily on (for testing purposes only)

 

*

Output steadily off

Output #1 Logic

F

  

3

 

*

NO

NC

Output #2 Logic

F

  

4

 

*

NO

NC

Cross-Traffic
Optimization (CTO)

F

  

5

 

*

Off - Door always activates when any crossing

Low - Door occasionally activates when crossing traffic is detected

Medium - Door rarely activates when crossing traffic is detected

 

High - Door ignores most crossing traffic

Interference Filter

F

  

6

 

*

Off 

On - Use when electromagnetic sources such as fluorescent bulbs,  
HID lights, wireless systems, motors/inverters are causing interference

Slow Motion 
Detection (SMD)

(People only)

F

  

7

 

*

Off 

On - holds door open as long as people are slightly moving in front of the door
(LED will blink)

Remote control  
communication  
address

F

  

8

Set Access Code 
(To unlock sensor 
see page 4)

Delete Access Code

D

  

9

i

Before setting access code, always use delete access code 

To set access code, enter   

D

  

   followed by any 4-digit number from 

1   1   1   1  -  9   9   9   8

  ending with 

D

. Access code is now stored.

To delete access code, enter  

D

  

   

9   9   9   9

  ending with  

D

.

Lock Sensor to  
Remote Access

F

  

8

 

Forces sensor to exit programming mode. 
Further changes cannot be made until programming mode is entered again 
(See section 5.1). 

Factory Reset

A

Completes factory reset 
All settings listed in this table with 

*

 will be restored.

* Factory settings

 

 

Available addresses that can be set by remote 

 

*

Factory setting

Reads & sets address (1-4) set by DIP switch on sensor unit 
Once address is changed, press  

G

  to re-establish connection with sensor

Содержание Herkules 2E

Страница 1: ...h dir People vehicles fwd People veh bkwd People veh both dir Field size Sensitivity Output 1 Output 2 D E X small least sens Small less sens Medium norm sens Large very sens Xlarge most sens Output H...

Страница 2: ...or to mounting bracket by aligning the pins and screws on the sensor with the slots on the mounting bracket Ensure both sides are seated properly Tighten handscrews to secure 6 Connect cable to door o...

Страница 3: ...ontinue to blink quickly The RegloBeam 2 remote control allows Herkules 2E to be easily and conveniently programmed from the ground Data transfer between the RegloBeam 2 and Herkules 2E functions in b...

Страница 4: ...letter button EXAMPLE mounting height The sensor acknow ledges it s current setting by illuminating it on the keypad EXAMPLE 4 5 m factory default Now press desired new value EXAMPLE Desired height 3...

Страница 5: ...rections People vehicles forward People vehicles backward People vehicles both directions Output 2 Configuration Red LED Pink grey wires In Out C Vehicles forward Vehicles backward Vehicles both direc...

Страница 6: ...motors inverters are causing interference Slow Motion Detection SMD People only F 7 Off On holds door open as long as people are slightly moving in front of the door LED will blink Remote control com...

Страница 7: ...vate the wide field setting If wide sensing field is desired follow programming instructions below and use the clip accessory on the sensor unit The sensor will not function correctly if the clip is u...

Страница 8: ...Bircher Reglomat AG reserves the right to make changes to any of the products described in this document without prior notice Fault Remedy People vehicle separation does not work as expected Check mou...

Отзывы: