4
L
R
The RegloBeam 2 functions bidirectionally with the sensor. This means
that changes to the settings on the sensor are immediately signalled
back by the sensor to the remote control. If an additional parameter is
programmed within 2 minutes of the previous parameter, it is not ne-
cessary to press
to re-establish connection to the sensor each
time.
The connection between the RegloBeam 2 and Herkules 2E can only be
established when the sensor is in programming mode (unlocked). Pro-
gramming mode is activated when the sensor is switched on. For sa-
fety reasons, this mode is automatically deactivated 30 minutes after
the last setting has been made on the sensor. The sensor can be locked
at any time by pressing
followed by
.
Programming mode can be activated in three different ways:
Ensure sensor is in
programming mode
(section 5.1)
Once
blinks, press
again to establish
connection.
The sensor’s address
illuminates on the
keypad.
EXAMPLE:
address
(factory setting)
Choose function to be
programmed. See
chart on following
pages for complete
list.
Press the desired
function (letter)
button.
EXAMPLE:
mounting height
The sensor acknow-
ledges it’s current
setting by illuminating
it on the keypad.
EXAMPLE:
= 4 – 5 m
(factory default)
Now press desired
new value.
EXAMPLE:
Desired height = 3 m
Choose
= 3 – 4 m
The new setting is
immediately saved and
displayed on the
keypad.
Programming of this
function is now
complete. Repeat for
other functions if
necessary.
i
Note: If any buttons are blinking, programming failed. In this case, repeat programming.
A) Restart the sensor
(temporarily disconnect the supply voltage)
B) Briefly press one of the buttons inside the sensor unit,
L or R
To access programming buttons, open the front cover of the sensor
by removing 4 screws.
Replace cover and close securely once button has been pressed.
C) Enter access code with remote control
1
2
Press
to establish connection to the
sensor. The sensor address will illuminate.
Press
followed by
and enter the
4-digit preset
access code
, followed by
.
EXAMPLE:
Sensor is now in programming mode.
If parameters cannot be changed (buttons
blink), repeat sequence.
If connection is still not established,
use option A or B above
(no access code
was previously stored.)
4.3
Establishing Connection to the Sensor
5.1
Establishing Connection to the Sensor
5
Functions & Settings - Programming by Remote Control