The RegloBeam 2 functions bidirectionally with the sensor. This means 
that changes to the settings on the sensor are immediately signalled 
back by the sensor to the remote control. If an additional parameter is 

programmed within 2 minutes of the previous parameter, it is not ne-
cessary to press  

  to re-establish connection to the sensor each 

time.

The connection between the RegloBeam 2 and Herkules 2E can only be 
established when the sensor is in programming mode (unlocked). Pro-
gramming mode is activated when the sensor is switched on. For sa-

fety reasons, this mode is automatically deactivated 30 minutes after 
the last setting has been made on the sensor. The sensor can be locked 
at any time by pressing   

  

  followed by 

.

Programming mode can be activated in three different ways:

Ensure sensor is in 

programming mode 

(section 5.1)

Once  

  blinks, press  

  again to establish 

connection. 

The sensor’s address 

illuminates on the 

keypad. 

EXAMPLE:  

address  

  

(factory setting)

Choose function to be 

programmed. See 

chart on following 

pages  for complete 

list.

Press the desired 

function (letter) 

button.

EXAMPLE:  

mounting height  

The sensor acknow-

ledges it’s current 

setting by illuminating 

it on the keypad.

EXAMPLE:

 

 = 4 – 5 m

(factory default)

Now press desired 

new value.

EXAMPLE:   

Desired height = 3 m 

Choose  

 

 

= 3 – 4 m

The new setting is 

immediately saved and 

displayed on the 

keypad. 

Programming of this 

function is now 

complete. Repeat for 

other functions if 

necessary.

i

   Note: If any buttons are blinking, programming failed. In this case, repeat programming.

A)  Restart the sensor 

(temporarily disconnect the supply voltage)

B)   Briefly press one of the buttons inside the sensor unit,

L   or   R  

To access programming buttons, open the front cover of the sensor 
by removing 4 screws.
Replace cover and close securely once button has been pressed. 

C)  Enter access code with remote control

1

2

Press  

  to establish connection to the 

sensor. The sensor address will illuminate. 

Press  

  followed by  

   and enter the 

4-digit preset 

access code

, followed by  

EXAMPLE:

   

  

  

  

  

   

Sensor is now in programming mode.

If parameters cannot be changed (buttons 
blink), repeat sequence.

If connection is still not established,   

use option A or B above

 (no access code 

was previously stored.)

4.3

Establishing Connection to the Sensor

5.1

Establishing Connection to the Sensor

5

Functions & Settings - Programming by Remote Control

Содержание Herkules 2E

Страница 1: ...h dir People vehicles fwd People veh bkwd People veh both dir Field size Sensitivity Output 1 Output 2 D E X small least sens Small less sens Medium norm sens Large very sens Xlarge most sens Output H...

Страница 2: ...or to mounting bracket by aligning the pins and screws on the sensor with the slots on the mounting bracket Ensure both sides are seated properly Tighten handscrews to secure 6 Connect cable to door o...

Страница 3: ...ontinue to blink quickly The RegloBeam 2 remote control allows Herkules 2E to be easily and conveniently programmed from the ground Data transfer between the RegloBeam 2 and Herkules 2E functions in b...

Страница 4: ...letter button EXAMPLE mounting height The sensor acknow ledges it s current setting by illuminating it on the keypad EXAMPLE 4 5 m factory default Now press desired new value EXAMPLE Desired height 3...

Страница 5: ...rections People vehicles forward People vehicles backward People vehicles both directions Output 2 Configuration Red LED Pink grey wires In Out C Vehicles forward Vehicles backward Vehicles both direc...

Страница 6: ...motors inverters are causing interference Slow Motion Detection SMD People only F 7 Off On holds door open as long as people are slightly moving in front of the door LED will blink Remote control com...

Страница 7: ...vate the wide field setting If wide sensing field is desired follow programming instructions below and use the clip accessory on the sensor unit The sensor will not function correctly if the clip is u...

Страница 8: ...Bircher Reglomat AG reserves the right to make changes to any of the products described in this document without prior notice Fault Remedy People vehicle separation does not work as expected Check mou...

Отзывы: