3
A
B
C
D
E
F
Function
Remote
Function
Values/
Description
Mounting
Height
A
2.0 – 2.5 m
2.5 – 3.0 m
3.0 – 4.0 m
4.0 – 5.0 m *
5.0 – 6.0 m
6.0 – 7.0 m
Output
Configu-
ration
Output #1
(Green LED)
Output #2
(Red LED)
B
C
Vehicles forward*
Vehicles backward
Vehicles both dir
People forward**
People backward
People both dir
People/vehicles fwd
People/veh bkwd
People/veh both dir
Field size/
Sensitivity
Output #1
Output #2
D
E
X-small/least sens.
Small/less sens.
Medium/norm sens.
Large/very sens.*
Xlarge/most sens.
Output
Hold Time
Output #1
Output #2
F
1
F
2
0.2 sec
0.5 sec
1.0 sec
2.0 sec*
5.0 sec
Pulse on exit
Output steadily on
Output steadily off**
* Factory Settings
** Factory Settings for output 2
Herkules 2E
350841A
12/15
Power
10 - 36 VDC/
12 - 28 VAC
White
Brown
Green
Cable
Yellow
Pink
Grey
Output 1
(Green LED)
COM
NO (NC)
Output 2*
(Red LED)
COM
NO (NC)
See table on pages 5 & 6 for detailed information
on output 1
See table on pages 5 & 6 for detailed information
on output 2
*Factory setting = Output 2 off
Startup sequence after power has been connected to the sensor:
-Both green & red LED’s begin to blink slowly
-Green LED will continue to blink quickly
The RegloBeam 2 remote control allows Herkules 2E to be easily and
conveniently programmed from the ground. Data transfer between the
RegloBeam 2 and Herkules 2E functions in both directions, i.e. to and from
the sensor by an infrared interface. The RegloBeam 2 reads back the ad-
justed values immediately after programming and displays them on the
remote to ensure accurate programming.
A
Transmitter/receiver (infrared)
B
Status indicator LED
C
Numerical buttons (1 to 9)
D
Function buttons (A to F)
E
Start button:
a) Powers on (hold 2 sec)
b) Establishes connection to the sensor
F
Remote function quick reference guide
(stored in slot on battery compartment cover)
This guide is included in every Herkules 2E box
The RegloBeam 2 must be powered on before use.
POWER ON:
Press and hold
G
for 2 seconds
POWER OFF*: Press and hold
G
for 2 seconds
* The remote will automatically turn off after 2 minutes if no
button is pressed.
i
3
Electrical Connection
4
Introduction to the RegloBeam 2 Remote Control
4.1
Layout of the RegloBeam 2 Remote Control
3.1
Intialisation
4.2
Turning on the RegloBeam 2 Remote Control
Flashing buttons on the RegloBeam 2 indicate that the data has
not been fully transmitted.
Avoid exposing the infrared interface to direct sunlight or other light sour-
ces.