CLEANING AND MAINTENANCE

FILTER PACK CLEANING/CHANGE 
FREQUENCY

It is necessary to change the filter pack once a 

year if the maintenance and cleaning advice has 

been followed, although this time may depend 

on the environmental situation of the area and 

the use of the CRU Biow.

In people with respiratory diseases or special 

sensitivity, as well as in public spaces subjected 

to a high concentration of volatile organic 

compounds, it is advisable to change the filter 

pack every time the equipment indicates as 

such. In these cases, you should not clean the 

filter pack, but replace it directly.

HOW TO KNOW WHEN TO CLEAN/CHANGE 
THE FILTER PACK

The CRU Biow has a sensor or filter pack change 

indicator, which counts its hours of use and will 

be automatically activated when it reaches this 

parameter, advising the user to clean or change 

the filter pack.

The filter pack change indicator will be shown on 

the screen, although the CRU Biow will continue 

to work normally.

HOW TO CHANGE THE FILTER PACK

It is a very simple process, so you can dismantle 

the filter pack yourself by fully unscrewing lateral 

knobs located at the bottom of the unit.

•  Take the filter pack out of the casing.

•  Remove the black pre-filter fixed with velcro, 

wash it with water, let it dry and replace it in 

the same position.

•  Clean the HEPA filter with your vacuum 

eliminating all visible dirt.

•  If the HEPA filter is in a good condition, 

replace the black pre-filter and reset the 

equipment pressing the timer button for 

3 seconds. The filter pack indicator will be 

deactivated and will notify you again after a 

few months.

 

If, once this process has been carried out, an issue 

with the operation of the equipment is detected, 

it may be due to the fact that the filter pack is 

clogged, obstructing the passage of air due to 

accumulated dirt. Check it and replace it, even 

if the filter pack change light is not illuminated.

•  If you notice that the HEPA filter is in a bad 

condition, it is recommended to replace the 

filter pack directly.

•  You can purchase a new filtering pack by 

calling 985 87 93 45

4.2. FILTER PACK CLEANING AND REPLACEMENT

IMPORTANT

BIOWAIR TOTAL SYSTEMS

only guarantees the effectiveness 
of the BIOW equipment using filter 
packs supplied by the manufacturer.

Cleaning filter pack 

watch video

Содержание biow 100

Страница 1: ...USER MANUAL CRU BIOW Regeneration Life...

Страница 2: ...Regeneration Life...

Страница 3: ...AL 15 2 9 WIFI PROGRAMMING MODE 15 2 10 DISPLAY 16 2 11 SAFE EQUIPMENT SHUTDOWN 18 2 12 HOW TO OPTIMISE MY CRU BIOW 18 3 3 BIOW APP ON DEMAND PROGRAMMING 20 3 1 BIOW APPINSTALLATION 20 3 2 ON DEMAND P...

Страница 4: ...l wear The device is not used by people with reduced physical sensory or mental capabilities Under no circumstances should the repair and internal handling of the device be carried out by staff who ar...

Страница 5: ...use of the device by a person responsible for their safety Some parts of this product can get hot and cause burns Special attention should be paid when children and vulnerable people are present The d...

Страница 6: ...20 kg We recommend not to place real flowers or other materials that may contaminate the air supply with pollen or other compounds 1 2 EQUIPMENT PARTS 1 Storage shelf 2 Manual ON OFF button 3 Display...

Страница 7: ...degree of protection IP 21 Maximum power 500W Operating mode Continuous MATERIALES Lower part High quality steel Upper part Compact high strength silicon CRU BIOW 100 MEASUREMENTS AND WEIGHTS Model de...

Страница 8: ...ent operating temperature 10 40 C Ambient storage transport temperature 0 45 C Relative air humidity 35 75 non condensing Air pressure 700 1060 hPa CRU Biow has an integrated base that enables you to...

Страница 9: ...the equipment to the wall as shown in the figure 2x Measurements to attach to the wall the CRU Biow 100 Minimumground clearance 850 mm Measurements to attach to the wall the CRU Biow 60 Minimumground...

Страница 10: ...will light up and from this moment on the equipment will be controlled by the remote control IMPORTANT Once the equipment is connected to the network ensure that the ON OFF switch remains easily acce...

Страница 11: ...te control until AUTO appears on the display To change speeds you must exit the AUTO mode From this moment on Biow can be operated autonomously regulating itself according to the level of contaminatio...

Страница 12: ...he level of particles and the light intensity of the room If there is light Speed according to need depending on the concentration of particles in the room ION UV selectable If there is not enough lig...

Страница 13: ...tes the activation and deactivation of the ultraviolet lights These work by increasing the elimination of microorganisms In AUTO mode they will be deactivated during the night TIMER Facilitates the ac...

Страница 14: ...that measures the amount of light in the room thus adapting its functionality to promote rest Speed with automatic adjustment according to the suspended particle concentration If the suspended particl...

Страница 15: ...light up showing the parameters of the last selected program 2 8 MODO MANUAL The CRU Biow allows full customization of its functionality Selection of the air treatment speed V Silent V White V2 y V3...

Страница 16: ...eneration Life 02 CRU BIOW OPERATION 2 10 DISPLAY Thermal treatment Heat mode Filter pack change message Ionization Ultraviolet light External temperature reader Operating mode Timer Speed Number of s...

Страница 17: ...shows the number of suspended particles in the room and this in turn indicates the air quality of the room which is shown with the acronym BPR Blood Pollution Risk It allows you to select different pa...

Страница 18: ...h hormones To increase the effectiveness of the CRU Biow it is recommended to place it on a flat surface ideally located in front of the bed and at the foot of the bed at the height of the mattress so...

Страница 19: ...ting it during the night 1 2 Particularly sensitive people may experience certain unpleasant sensations such as slight nasal obstruction or a scratchy throat If this happens temporarily disconnect the...

Страница 20: ...pment is powered on 2 Access the Biow application by downloading it from the App Store or Play Store In one simple step create your Biow account username and password which you can access from differe...

Страница 21: ...this procedure may change depending on the type of mobile but in any case you must do it from the WIFI settings 4 Press the UV button for three seconds From the remote control of your CRU Biow until...

Страница 22: ...image below so that it will be reset when searching The Biow network may require1minute to appear NOTE Reset the equipment for 10 seconds unplugging it from the socket to start the process again if a...

Страница 23: ...works will be displayed Select the network you are interested in and the corresponding password will be included if the network is open the Confirm button will be pressed without including any type of...

Страница 24: ...t the WIFI symbol is no longer flashing or crossed out 11 You can start now Program your Biow CRU in a fully personalized way and monitor its activity from the Biow APP From here you will be able to c...

Страница 25: ...e from the physical remote control 2 We will also be able to access the programming from the upper right button 3 Once this button has been pressed a menu will appear where the operating mode of the C...

Страница 26: ...unit wiring and external air is recommended If you detect damage deformation or rupture of any of these elements please contact with your distributor or contact Biowair Total Technical Service System...

Страница 27: ...ss so you can dismantle the filter pack yourself by fully unscrewing lateral knobs located at the bottom of the unit Take the filter pack out of the casing Remove the black pre filter fixed with velcr...

Страница 28: ...ilization system in heat mode The CRU Biow incorporates a pre filter that can be easily washed Only water should be used to clean this filter and dry it completely before replacing it in the equipment...

Страница 29: ...ono Industrial Roces C Michel Faraday n 75 naves 9 y 10 33211 Gij n Asturias ESPA A www biow es 5 2 SPARE PARTS AND ACCESSORIES You can purchase them through your distributor or by calling customer se...

Страница 30: ...of the device negligence wear and tear breaks incorrect installation and incorrect power supply to the device This guarantee is also excluded if the product is used for any other purpose than the ind...

Страница 31: ...subject to separate collection at the end of its life cycle This indication is valid for the device as well as for any equipment marked with this symbol Disposing of these devices correctly you will h...

Страница 32: ...e in the room Press the button and you will see the thermostat temperature on the screen The protection of the heat generating resistors may be activated This can happen if the air outlet of the equip...

Страница 33: ...k that the heat mode is not activated since for safety reasons the air flow is increased in this function by automatically changing to V White My equipment turns on and off automatically Check if you...