2.5. ADDITIONAL FUCTIONS
The following table summarizes the use and functionalities of the equipment using the remote
control, pressing the indicated buttons for 3 seconds.
It will display 3 pollution sensor measurements depending on the molecular weight: PM1
– PM 2,5 – PM Nanoparticles.
The reading of the 3 particle levels will not appear until there is a variation of particles
in the environment.
MODE
Buzzer that beeps when each function is activated on the remote control.
UV
Activates WIFI mode (see detail in section 4).
Resets the equipment after changing the filter pack. This will remove the filter pack
change icon from the display.
Change in particle measurement according to its size.
PM1 – PM2,5 – PM Nanoparticles.
Complete shutdown of the display illumination to promote rest.
2.6. AUTO MODE
When you activate your CRU Biow for the first
time, it will start operating in AUTO mode in
order to make it easier to handle for all users.
This operating mode provides the user with
absolute comfort due to two factors:
1. Automatic adaptation of the equipment to
the environmental variations of the room.
2. Noise reduction and dimming of the display
brightness in case of low light in the room,
in order to promote rest. The CRU Biow
has an optical sensor that measures the
amount of light in the room, thus adapting
its functionality to promote rest.
Speed with automatic adjustment according to
the suspended particle concentration:
• If the suspended particles exceed the
limit of 25
µ
g, the “Blood Pollution Risk
Nanoparticles” indicator will turn yellow, and
the equipment will automatically switch to
V2 speed to reduce the level of suspended
particles more quickly.
• If the suspended particles exceed the
limit of 150
µ
g, the “Blood Pollution Risk
Nanoparticles” indicator will turn red, and
the equipment will automatically switch to
V3 speed para reducir más rápidamente el
nivel de partículas en susp . . . . . . . . . .
ensión.
• to reduce the level of suspended particles
more quickly.
• If the CRU Biow sensor detects a drop in the
light level in the room, after 3 seconds, the
speed will switch to V SILENT and the display
illumination will be dimmed to promote
rest. After 20 seconds, the display will shut
down completely except for the symbol
and the symbol indicating V SILENT.
.
• When the CRU Biow is operating in V SILENT
mode and the heat is activated, the speed
will automatically switch to V WHITE
. If
you want to switch back to SILENT mode,
you must switch off the heat mode by
pressing the button
.
• Although in AUTO mode the operating
speed is automatic depending on the level of
suspended particles, you can also adjust the
speed at will by pressing the central button
on the remote control
.
However, when this is done, the equipment will
switch to manual mode directly.