![Biotech Top Light Zero 18 Скачать руководство пользователя страница 37](http://html.mh-extra.com/html/biotech/top-light-zero-18/top-light-zero-18_user-manual_2756058037.webp)
37
• Open the lower cleaning hatch.
• Extract the ash container and empty it out.
• Open the upper cleaning hatch and place the ash container beneath it.
• Remove any fly ash which has accumulated on the combustion chamber bulkhead (a scraper for this purpose can
be obtained from Biotech or your dealer).
• Use a vacuum cleaner to remove any residual ash so that the combustion chamber is completely clean.
• Use a suitable vacuum cleaner to clean any residual ash out of
the ash compartment as well.
• Place the ash container back in its compartment.
• Close the cleaning hatches.
• Press the "Empty ash" button in the "Maintenance" menu
to confirm that the system has been cleaned.
• The removed ash can be used as compost or
disposed of with biological waste.
• Start the system up again.
This job can also be done by our customer service technician
during the yearly overhaul!
Содержание Top Light Zero 18
Страница 38: ...38 08 Notes ...