Overview
BioSmart 5M-O Controller is designed for identification of users by fingerprints and RFID cards. It
can also control a lock or a turnstile (from one side only).
BioSmart 5M-E is a modification of BioSmart 5M-O designed to operate at the below zero
temperatures (in Celsius). The controller is equipped with a capacitive fingerprint scanner that
improves the quality of biometric identification. The controller internal elements have special
protection against corrosion and condensate, making device suitable for outdoor application.
Fingerprint scanner is equipped with a heating circuit that ensures comfortable scanning even at
low temperatures down to -40 °С.
Controller is compatible with BioSmart Studio software version V5.7.0 and above.
Specifications
Parameters
5M-O
5M-E
Authentication types
Biometric or card
Card + biometric
Biometric or card
Card + biometric
Users
1000
1000
Fingerprint templates
4 500
4 500
Event log capacity
25 000
25 000
Match time (1:1000) in local mode, by
fingerprints
< 970 ms
< 970 ms
Verification time (1:1)
< 600 ms
< 600 ms
FAR (False Acceptance Rate)
10
-4
-10
-8
10
-4
-10
-8
FRR (False Rejection Rate), at FAR = 10-5**
1%
1%
Sensor technology
Optical
Capacitive
Image size
272 x 320
272 x 320
Resolution
500 dpi
500 dpi
Smart card reader
HID Prox/iClass/iClass SE
(125 kHz / 13.56 MHz)
Legic Advant (13.56 MHz)
EM Marin (125 kHz)
HID Prox/iClass/iClass SE
(125 kHz / 13.56 MHz)
Legic Advant (13.56 MHz)
EM Marin (125 kHz)
LED indication
Tri-color (blue, red, green) Tri-color (blue, red, green)
Communication
Ethernet (100 BASE-T),
Ethernet (100 BASE-T),