BioSmart 5M-E Скачать руководство пользователя страница 3

 

          

                     

 

BioSmart 5M-O/5M-E Installation Guide v1.2|10.2018|en

 

Safety Instructions 

Safety instructions must be followed in addition to International Standards (ISO/IEC)

*

, and other 

safety regulations. 

 

Caution

 

Caution indicates a hazard with a low level of risk which, if not avoided, could 
result in minor or moderate injury. 

 

Note

 

Note indicates an 

important

 remark, which should be taken into attention. 

 

 

Caution

 

General requirements:

 

 

Read, follow and retain instructions – All safety and operating instructions 
must be read and followed properly before putting the unit into operation. 

 

Do not turn on the power supply until all installation procedures are 
finished 
– this may lead to injury or equipment damage.  

 

Do not disconnect or connect cables while unit is powered on – this may 
lead to unit malfunction and software errors. 

 

Do not expose unit to heat or fire – high temperature impact may lead to 
case deformation and circuit board damage.  

 

Make sure that all cables and screws are fastened properly - otherwise 
case damage or circuit shortcut may happen

 

Note

 

Additional requirements:

 

 

Use a clean, dry cloth to remove any dirt or dust from the unit. 

 

 

 

 

 

 

 

 

*IEC 60204-1: Safety of machinery – Electrical equipment of machines. (Part 1: General requirements) 

 

Содержание 5M-E

Страница 1: ...BioSmart 5M O 5M E Installation Guide www biosmart tech com...

Страница 2: ...ions 5 Package contents 5 Opening the case 6 Circuit board 7 Circuit board LEDs and jumpers 7 Connector names and description 7 2 Installation 8 Cable types 8 General installation notes 8 Mounting on...

Страница 3: ...d followed properly before putting the unit into operation Do not turn on the power supply until all installation procedures are finished this may lead to injury or equipment damage Do not disconnect...

Страница 4: ...emperatures down to 40 Controller is compatible with BioSmart Studio software version V5 7 0 and above Specifications Parameters 5M O 5M E Authentication types Biometric or card Card biometric Biometr...

Страница 5: ...DC 1A Tamper detection 1 sensor on case opening 1 sensor on case opening Power requirements 12VDC 15 0 5 A 12VDC 15 0 5 A PoE Power over Ethernet None None Operating temperature 0 50 C 40 50 C Housing...

Страница 6: ...LED indicator Blue waiting mode Green identification successful Red identification failed RFID card reader RFID card identification Fingerprint scanner Fingerprint identification Package contents Item...

Страница 7: ...6 BioSmart 5M O 5M E Installation Guide v1 2 10 2018 en Opening the case 1 Remove the back cover retaining screw 2 Detach the case from the back cover to access the circuit board...

Страница 8: ...wer supply ground Power supply 2 12V 12VDC Power supply Power supply 3 REL Relay output Fail safe lock Fail secure lock turnstile 4 REL Relay output Fail safe lock Fail secure lock turnstile 5 IN Disc...

Страница 9: ...Four twisted pair cables of no lower than category five with a wire size of no less than 0 2 mm2 General installation notes Install the controller on vertical surface Cables must be installed in acco...

Страница 10: ...ing template and insert dowels inside the holes 3 Place back cover on wall and fix it with self tapping screws 4 Connect power supply lock and buttons if needed according to p 2 4 2 8 Put cables throu...

Страница 11: ...Attach the case and fix the retaining screw Power supply connection Use a DC 12 V power supply adaptor with a minimum of 0 500 mA which has obtained the approval of IEC EN 60950 1 See recommended cabl...

Страница 12: ...of connections in the cable s modular connector must correspond to the TIA EIA 568 B standard Locks connection See recommended cable type in Cable types table Install a diode as it shown on figure to...

Страница 13: ...E Installation Guide v1 2 10 2018 en Caution Turn on Relay inversion in BioSmart Studio v5 if connecting an electromagnetic lock Exit buttons and door sensors connection See recommended cable type in...

Страница 14: ...13 BioSmart 5M O 5M E Installation Guide v1 2 10 2018 en Wiegand output connection See recommended cable type in Cable types table...

Страница 15: ...Support support biosmart tech com 420 246 097 126 Skype BioSmart TechSupport 420 246 097 126 Konevova 2660 141 130 00 Prague Czech Republic www biosmart tech com sale biosmart tech com...

Отзывы: