background image

 

          

                     

 

BioSmart 5M-O/5M-E Installation Guide v1.2|10.2018|en

 

ZFlex Relay Module support 

None 

None 

WIEGAND I/O 

Output, 26/32 bit 

Output, 26/32 bit 

Discrete inputs 

Onboard lock control relay 

12VDC, 1A 

12VDC, 1A 

Tamper detection 

1 sensor 

– on case 

opening 

1 sensor 

– on case 

opening 

Power requirements 

12VDC

±15%, 0.5 A 

12VDC

±15%, 0.5 A 

PoE (Power over Ethernet) 

None 

None 

Operating temperature 

0 … +50°C  

-40 

… +50°C  

Housing type 

Aluminum, wall mount 

Aluminum, wall mount 

Dimensions (H x W x D) 

160 x 50 x 43 mm  

160 x 50 x 43 mm  

Weight 

260 g  

260 g  

Warranty 

5 years 

5 years 

Note: *     - Each user can be provided with single card code 

 

 

 

Содержание 5M-E

Страница 1: ...BioSmart 5M O 5M E Installation Guide www biosmart tech com...

Страница 2: ...ions 5 Package contents 5 Opening the case 6 Circuit board 7 Circuit board LEDs and jumpers 7 Connector names and description 7 2 Installation 8 Cable types 8 General installation notes 8 Mounting on...

Страница 3: ...d followed properly before putting the unit into operation Do not turn on the power supply until all installation procedures are finished this may lead to injury or equipment damage Do not disconnect...

Страница 4: ...emperatures down to 40 Controller is compatible with BioSmart Studio software version V5 7 0 and above Specifications Parameters 5M O 5M E Authentication types Biometric or card Card biometric Biometr...

Страница 5: ...DC 1A Tamper detection 1 sensor on case opening 1 sensor on case opening Power requirements 12VDC 15 0 5 A 12VDC 15 0 5 A PoE Power over Ethernet None None Operating temperature 0 50 C 40 50 C Housing...

Страница 6: ...LED indicator Blue waiting mode Green identification successful Red identification failed RFID card reader RFID card identification Fingerprint scanner Fingerprint identification Package contents Item...

Страница 7: ...6 BioSmart 5M O 5M E Installation Guide v1 2 10 2018 en Opening the case 1 Remove the back cover retaining screw 2 Detach the case from the back cover to access the circuit board...

Страница 8: ...wer supply ground Power supply 2 12V 12VDC Power supply Power supply 3 REL Relay output Fail safe lock Fail secure lock turnstile 4 REL Relay output Fail safe lock Fail secure lock turnstile 5 IN Disc...

Страница 9: ...Four twisted pair cables of no lower than category five with a wire size of no less than 0 2 mm2 General installation notes Install the controller on vertical surface Cables must be installed in acco...

Страница 10: ...ing template and insert dowels inside the holes 3 Place back cover on wall and fix it with self tapping screws 4 Connect power supply lock and buttons if needed according to p 2 4 2 8 Put cables throu...

Страница 11: ...Attach the case and fix the retaining screw Power supply connection Use a DC 12 V power supply adaptor with a minimum of 0 500 mA which has obtained the approval of IEC EN 60950 1 See recommended cabl...

Страница 12: ...of connections in the cable s modular connector must correspond to the TIA EIA 568 B standard Locks connection See recommended cable type in Cable types table Install a diode as it shown on figure to...

Страница 13: ...E Installation Guide v1 2 10 2018 en Caution Turn on Relay inversion in BioSmart Studio v5 if connecting an electromagnetic lock Exit buttons and door sensors connection See recommended cable type in...

Страница 14: ...13 BioSmart 5M O 5M E Installation Guide v1 2 10 2018 en Wiegand output connection See recommended cable type in Cable types table...

Страница 15: ...Support support biosmart tech com 420 246 097 126 Skype BioSmart TechSupport 420 246 097 126 Konevova 2660 141 130 00 Prague Czech Republic www biosmart tech com sale biosmart tech com...

Отзывы: