17
6. Checkpoints after Installation
●
Before supplying water to the main unit, drain the running water by opening the
valve at the water meter and opening one of the water taps in the building. Do not
open the outlet faucet at this time.
(This is to drain any foreign substances from the running water piping, thereby
preventing malfunction of the built-in Solenoid valve)
●
Check for leakage at the pipe connection by pushing the POWER button.
(Do not push the switch for 3 seconds after water supply has begun.)
Leave the valve at the water meter open.
(Open the valve at the water meter which
was closed to connect the intermediary
valve.)
Open one of the running water taps to
drain foreign substances, if any.
Turn on the product by pushing the POWER button, select the purification function, and
drain about 10 liters of water (about 5 minutes).
- This is to remove any air bubbles and fine particles from the activated carbon in the filter.
Check for water leakage at piping connections and the filter.
- To check leakage at the filter, open the filter cover.
* Make sure that water comes out of the drain outlet
(acidic ionized water outlet faucet).
(If no water comes out, check if any part of the drain
hose is bent.)
Leave the (small) adaptor adjustment
screw of the intermediary valve. (The
product is shipped with the screw open.)
Insert the plug of the product into
the receptacle. (You should hear
beeping sound.)
Check the operation of the control panel
by pressing the POWER button.
(Make sure that the lamps on the
control panel turn on normally during
the different operation steps.)
Drain outlet
(Acidic ionized water)
Alkaline
outlet
faucet
Содержание BTM-105DN
Страница 12: ...12 2 Parts Drawing for Installation Check the positions of parts and accessories...
Страница 29: ...29 How to use cleaning filter ACID ALK PU ACID ALK PU...