Repair work at the humidifying and dehumidifying system
1
•
Steam hose (tissue), 1200 mm / 47.24 in
2
•
Pressure hose with metal braiding
3
•
Reflux valve
4
•
Water pump for steam boiler (-
9M10
)
5
•
Valve block pressure controller complete
- Valve block with safety valve
- Manometric switch with relay (
-9F30
)
- Solenoid valve steam outlet (-
9Y10
)
- Screw nut for valve block
- Squeezing ring for valve block
6
•
Pressure compensation hose to outlet tank, 730 mm /
28.47 in
7
•
Pressure compensation hose to outlet tank, 720 mm /
28.35 in
8
•
Suction hose for water pump (-
9M10
), 800 mm / 31.49 in (freshwater)
9
•
Control board humidification module (-
9N10
)
10
•
Pilot lamp, red 230 V
11
•
Evacuation pump 200 - 240V, 50 / 60 Hz (-
8M1
)
12
•
Power contactor (-
9K10
)
13
•
Freshwater inlet hose: Water hose ½", length: 450 mm
•
Hose clamp 12-20 mm / 0.47 x 0.79
14
•
Tank connection
15
•
Tipping float switch (-
10S2
)
16
•
Float switch (filling level and overflow sensor) (
-10S1
)
17
•
Square tank, outlet
18
•
Square lid, outlet
19
•
Diode (max. 240 VDC), (-
10V2
)
20
•
Condensate outlet hose ½" outer chamber
KBF 115: 1360 mm /
53.54 in
KBF 240: 1450 mm /
57.09 in
KBF 720: 1650 mm / 6496 in
•
Hose clamp 20-32 mm / 0.79 x 1.26 in
21
•
Air relief hose of reflux valve, 700 mm (freshwater)
22
•
Square tank, inlet
23
•
Square lid, inlet
24
•
Cable nozzle D10 mm
25
•
Tank fixing sheet
26
•
Hose holder fix ½"
27
•
Tipping float switch (-
10S3)
)
28
•
Solenoid valve 24 V, 0.2 - 10 bar, freshwater inlet valve (-
10Y1
)
Service Manual KBF (E5.2) 04-2015
99