MGR-TL/P
MGR-TL/P
Active
Non-Active
Press the peak hold operation
button to enable/disable the peak
hold function.
●
PEAK hold setting
1
)
Changing the settings
When the peak hold function is on,
the peak hold function will operate
after the device reaches the set
torque, which will leave the maximum
measurement value displayed on the
screen. To continue measuring, press
the power operation button to clear
the measurement results.
※
If the results are not cleared, only the maximum measurement value will be displayed on the screen;
the buzzer will not sound even if the set torque is reached and the grip will not vibrate.
2
)
Clearing the measured result
MGR-TL/P
2
)
Changing the settings
3
)
Confirming the setting
Press each operation button to select the preceding
or following setting.
The panel will cycle through the following items each time the peak hold operation
button is
pressed. (Pressing the power operation button will cycle in reverse order.)
MGR-TL/P
Backward
Forward
Pressing and holding the peak hold operation button will select the setting currently displayed on the
screen. The screen will then display the set torque and the device will return to working mode.
MGR-TL/P
Press and hold the peak hold operation button
Set torque displayed
Returns to working mode
19