ALARMS
DESCRIPTION
TYPE OF INTERVENTION
EH1A NTC Cold
It occurs if the temperature probe of the
cool unit goes to short circuit or the circuit
is open. The resistance will be switched
off if NTC is in short circuit or open. Upon
start up a 30 sec delay is expected prior to
alarm check.
Installer
EC1C Tcoffee<60°C
Referred to boiler 1. It occurs if upon reset
the set temperature minus 15°C is not rea-
ched in 15 minutes or if during the regular
operation the temperature remains below
60° for 15 minutes. Applicable to single
boiler or for coffee boiler if the double boiler
is enabled.
Installer
EC2C Tinstant<60°C
Referred to boiler 2. It occurs only if the
double boiler is enabled and if upon reset
the set temperature minus 15°C is not rea-
ched in 15 minutes or if during the regular
operation the temperature remains below
60° for 15 minutes.
Installer
EDF Sugar
It occurs if the 10 s timeout lapses duringthe
sugar conveyor movement.
Installer
EGN Too full
It occurs 2 sec.after the too full condition of
the liquid collecting tank micro is found.
Installer
ECK No Espansion
It occurs if components managed by any
expansion are enabled.
Installer
8.2.3 Stored signallings
EDT Grinder X
It occurs if the programmed grinder timeout
lapses. The display will show the ‘Without
coffee” message.The amount is re-credited
only in case of instant grinding. X=1 or 2
Installer
EEK Group
It occurs if the programmed coffee group
timeout lapses. The display will show the
“Without coffee” message. The amount is
re-credited.
Installer
EEJ No Group
It occurs if the group presence micro is
NA.
Installer
EFN ESP Pump
It occurs during the coffee water dispensing
if at least 10 cc are not provided in the
programmed pump timeout.The display will
show the “Without coffee” message. The
amount is re-credited. The boiler resistance
will be switched off until the error is reset.
Installer
EFN INSTANT pump
It occurs during the water dispensing of
instant products or hot water if at least half
dose is not provided in the programmed
pump timeout. The display will show the
“Espresso only” message. The amount is re-
credited if hot water was not being dispen-
sed.The boiler resistance will be switched
off until the error is reset.
Installer
EDU Dose vol 1
It occurs if after the coffee release phase
the dose micro remains pressed.The display
will show the “Without coffee 1” message.
The amount is re-credited.
Installer
EDU Dose vol 2
It occurs if after the coffee release phase
the dose micro remains pressed.The display
will show the “Without coffee 2” message.
The amount is re-credited.
Installer
Water empty
For machine with cool unit only. It occurs in
one of the following two cases:
1. Water is not at Min Lev (with approx.
2 sec.delay).2. The 4 min timeout for the
water loading ev lapses.The display will
show “Cold drinks only” message.