BIANCHI VENDING BVM952 Скачать руководство пользователя страница 51

51

In the management program Bianchi telemetry uses three tran-
smission systems:
SMS
GSM
GPRS

SMS

Sending the alarms generated by the machine to the central 
unit,fi ling and returning to the selected number for a quick in-
tervention.

SMS Example:

950E*ECE*280205*1008 

where the fi rst fi eld specifi es the type of machine,the second the 
event and the third and fourth the date and time.
Moreover, it is possible to use the Win Modem program allowing to 
manage the customer machine fl eet so to rationalize any technical 
intervention.
If an e-mail message is not sent successfully, the manager will 
receive an SMS notifi cation.
If the SMS messages are not sent successfully, 3 attempts will be 
made, at intervals of 5 minutes, repeated every hour.

 

GSM

Via the VMC-Central Unit direct connection through the GSM 
modems it is possible to download the distributor settings offl ine 
and modify them. It is also possible to request the updated sale 
data.

The Program for the remote management of the Audit data of 
Bianchi distributors is managed as follows:

The graphic presentation of the form includes a list containing the 
information about the type of distributor, telephone number of the 
GSM installed on the board and the sale point of the distributor.

By pressing the Audit Read key it is possible to call the remote 
machine.

After the connection is established, which is monitored via labels 
on the form, the data download will start. At the end of this ope-
ration a CommonDialog will be displayed (Save File with name) 
allowing to save the fi le in the  “.prm” format, i.e. with an extension 
comptabile with WinBianchi (e.g.: BVM970. prm).

Via the WinBianchi\ WinSoftwareAperto  program in OFF-LINE 
mode, it is possible to open this fi le later to monitor the data or 
to modify them.

After modifying the fi le, it is possible to save it with another name 
or to overwrite it. Now the fi le must be returned to the remote 
machine using the Write all key to re-write the entire machine 
confi guration or using the Write Select key to re-write only the 
modifi ed data.

GPRS

The sending of e-mail messages with EVA audit data can be adju-
sted from PC on fi xed days and timetables. Moreover it is possible 
to select when  to reset the resettable data. It is possible to receive 
e-mail messages also with the distributor error. The e.-mail mes-
sage with the EVA-TDS data is sent at the established time and 
therefore the clock chip is required. At the end of this operation 
the card will generate a Beep.

If any e-mail message is not sent successfully, 5 attempts will be 
made at intervals of 5 minutes, repeated every 6 hours.

To use the GPRS section the SIM card must be confi gured  by 
enabling the password for the connection to the internet network 
and setting the connection strings on the card; these operations 
are to be made by the different providers and are at customer’s 
charge.

All SMS-GSM-GPRS connection and transmission test are made 
with TIM, the use of other providers will not ensure the correct 
operation, in particular as far as GPRS section is concerned.

In the machine, in the “Remote connection” menu the following 
data can be displayed:

Signal intensity  

  In line 2 the display will show the GSM signal 

intensity, the  network registration status and 
the presence of GPRS network.

The signal intensity can range from 0 to 31 and if the signal cannot 
be found the value 99 will be displayed.

The value of the network registration status can range from 0 to 
5 according to the meaning:

0 - network not found or absent;

1 - ok, registered in the network of its own provider;

2 – not registered, searching network;

3 - network found but registration not allowed;

4 – network status indetermined;

5 - registered in roaming with another provider.

If GPRS network is present a G will be displayed.

 

 

SIGNAL INTENSITY

         19 

    

 1 

      G

GSM Signal Intens.

Registration to the network

GPRS network 

Via WinBianchi the following can be programmed:

APN 

  Access Point Name - identifi es the node for 

Internet access used by GPRS connection. 
Provided by the chosen provider.

USER ID 

 User identity for GPRS access. Provided by 

the provider.Some providers do not use it 
(for example: Tim uses the SIM telephone 
number as user-id, whereas Wind does not 
require it ; in this case write “none”).

PASSWORD  

 Password for GPRS access. Viene fornito 

dall’operatore. Provided by the provider. As 
for the User ID, some providers do not use 
it The max number of characters is 15 (for 
example: Tim provides the password, whe-
reas Wind does not require it ; in this case 
write “none”).

SERVER SMTP 

  Address of the outgoing mail server. Provided 

by the chosen provider.

 EMAIL RECEIVER    is the e-mail address to which the e-mail 

messages with Audit data must be sent.

Содержание BVM952

Страница 1: ...BVM972 BVM952 CERT N 9105 BNVD UNI EN ISO 9001 2000 USE AND MAINTENANCE MANUAL...

Страница 2: ......

Страница 3: ...0335 2 75 2003 06 Special requirements for commercial dispensers and automatic vending machines EN ISO 11201 EN ISO 3744 Measurement of acoustic noise 2 ELECTROMAGNETIC COMPATIBILITY EMC EN 55014 1 Em...

Страница 4: ...its service life to the appropriate separate collection centres for electronic electrotechnical waste products or return it to the dealer when purchasing a new equivalent equipment The appropriate se...

Страница 5: ...ned as the person responsible for the installation of the automatic distri butor the starting up operations and the function settings Each regulation operation is the exclusive responsibility of the i...

Страница 6: ...SCREWDRIVERS Small size Medium size Large size Normal cross Small cross Medium cross Large cross Of Te on small size for Trimmer regula tion RATCHET SPANNER no 14 TESTER ELECTRICIAN S SCISSORS PROGRA...

Страница 7: ...duct loading 4 6 1 Product container loading 4 6 2 Cup loading 4 6 3 Spoon loading 4 6 4 Spent coffee grounds bag insertion 4 7 Automatic distributor layout 4 8 First self installation mode 5 0 SOFTWA...

Страница 8: ...as such must always remain inside of the same so as to allow further consultations on the part of the various operators until the dismantlement and or scrapping of the machine In case of loss or dama...

Страница 9: ...e user must not in any circumstance be able accede to those parts of the automatic distributor that are protected and require a tool in order to be accessible The knowledge and the absolute respect fr...

Страница 10: ...mm 1620 mm Width B 666 mm 666 mm Depth C 776 mm 776 mm Weight 140 kg 190 kg 3 155 kg Power Supply V230 V230 Power frequency Hz 50 Hz 50 Installed power 1 1 8 kW 3 2 kW 1 8 kW 3 2 kW Nominal current Ma...

Страница 11: ...1 2 1 Coffee group and grinder 2 Drink dispensing group 3 Sugar dispenser group 4 Payment system 5 Cup column 6 Electronics board CPU 7 Power card 8 Spoons column 9 Water softener lter 10 Water bin 1...

Страница 12: ...d grinder 2 Drink dispensing group 3 Sugar dispenser group 4 Payment system 5 Cup column 6 Electronics board CPU 7 Power card 8 Spoons column 9 Water softener lter optional 10 Water bin 11 Dispensing...

Страница 13: ...rate and make the cup fall into the cup ring inside the cup dispenser Fig 2 1 2 1 2 SUGAR DISPENSER The sugar is dispensed directly in the cup in the E versions whereas for the I versions it is pre mi...

Страница 14: ...the brew chamber the rotation group geared motor brings it into the dispensing position and simultaneously compresses the ground coffee Fig 2 4 Fig 2 5 the pump that dispenses the quantity of program...

Страница 15: ...al of the various processes described here below can be activated If present the whipper motor is activated Fig 2 8 The electro valve xed on the soup boiler Fig 2 9 or on the coffee boiler Fig 2 10 it...

Страница 16: ...les and by a transparent lm in polypropylene Fig 3 2 The automatic distributor will be delivered packed assuring both a mechanical protection and protection against damages from the external environme...

Страница 17: ...ents listed here below cup turret example in Fig 3 7 coin box sugar container weight on the spoon dispenser column coin mechanism cover Master board product containers water bin oat mechanism bottom s...

Страница 18: ...ts dirty due to accidental spilling of the products use if necessary under the distributor a protection suf ciently wide to cover the distributors operating space 6 2 Connection to the main water supp...

Страница 19: ...reason verify the plant s earth wire connection to ascertain that it is ef cient and it answers national and European safety electric standards If necessary require the intervention quali ed personne...

Страница 20: ...some operations is however necessary operate with the door open but with the distributor connected It is possible for installation technician to operate in this way by inserting the special plastic ke...

Страница 21: ...start to heat up water in the boiler SINGLE STAINLESS STEEL BOILER FOR SOUPS At the output of BV lines the distributor will be put in condition of FIRST INSTALLATION As soon it reaches the location t...

Страница 22: ...n with a chlorine base products that can be purchased in pharmacies carefully fol lowing the indications on the product instruction labels remove all the product containers from the distributor Fig 4...

Страница 23: ...llation open the board and coin mechanism protection door Fig 4 21 Connect the payment system Fig 4 22 to the Master board The selectors must be directly connected to the Master board the and the seri...

Страница 24: ...ndicated on the label Fig 4 27 pay attention that they there are no clots avoid pressing the product and using an excessive quantity so as to avoid its aging in relation to the consumption forseen in...

Страница 25: ...lumn is not aligned with the distribution outlet then ll all the columns proceeding in an anti clockwise sense opposite sense when the column is aligned with the distribution outlet close the door and...

Страница 26: ...ve the wrapping Fig 4 31 once the loading is completed put the weight back in the spoon dispensing column Check that the spoon are cut burr free that they are not bent and that they are all placed hor...

Страница 27: ...each electrovalve can be coupled to 2 products at most These couplings are factory made therefore for a correct use of the distributor we should keep strictly to the following indications FIRST SOUP S...

Страница 28: ...ve can be coupled to 2 products at most These couplings are factory made therefore for a correct use of the distributor we should keep strictly to the following indications FIRST SOUP SECOND SOUP EV1...

Страница 29: ...most These couplings are factory made therefore for a correct use of the distributor we should keep strictly to the following indications FIRST SOUP SECOND SOUP EV1 Broth 0 EV2 Tea 0 EV3 Coffee Sugar...

Страница 30: ...ion can be combined creating a maximum sequence of 3 electrovalves each electrovalve can be coupled to 2 products at most These couplings are factory made therefore for a correct use of the distributo...

Страница 31: ...e combined creating a maximum sequence of 3 electrovalves each electrovalve can be coupled to 2 products at most These couplings are factory made therefore for a correct use of the distributor we shou...

Страница 32: ...e 3 way Coffee EV throughout the procedure The procedure will be carried out with resistance off At the end a date will be shown on the display For Instant boiler When the distributor is started up th...

Страница 33: ...ine BVM970 BVM 950 BVM 921 BVM600 BVM470 Manag Cold X Selects the type of management of the cold compressor 0 Snack Pan Can Menu available only with machine type BVM600 BVM470 1 None Cold management n...

Страница 34: ...ion Below are two examples of a machine with PAN con guration with the following data Tank temperature 2 Delta temperature 2 Offset temper 0 Delta safety 5 therefore safety temper 5 2 7 Safety time 2...

Страница 35: ...Bianchi only Code Keyboard Enables the management of the alphanume ric keyboard for Hot Distributor On Off It enables the selection code in the Times and Doses Menu Code keyboard In the programming mo...

Страница 36: ...e from last selection Q ty of water to be increased 3 ore 2 cc 6 ore 3 cc 9 ore 5 cc 12 ore 6 cc Type BVM600 Selects the type of management of cold compressor Snack Pan Menu available only with machin...

Страница 37: ...ot with four full squares and four empty squares Given that the sugar management of this option follows the formula Sugar A B 8 Where A Sugar dose in the doses menu for every drink B Sugar dose in the...

Страница 38: ...e 70 90 C The wording Slave X indicates the slave number linked to the MASTER distributor Managed by WinBianchi only Boiler Temp 2 Slave X Boiler 2 temperature Espresso boiler has a range 70 110 C Ins...

Страница 39: ...hine by entering the code 98 within 30 sec of buzzer operation If the inner temperature reaches the value set as safety value the selections from 51 to 68 are stopped and automatically made NOT AVAILA...

Страница 40: ...managed only on the selections enabled to this process Extra Coffee Time 0 5sec The user presses the Extra coffee or strong coffee preselection and then short coffee for example The Grinder will grind...

Страница 41: ...oupled to 1 E V 0 25 5 s Ton product X T on motoreducer second product 0 25 5 s The selected drink will be prepared with the quantity of sugar requested by the user Every square corresponds to x sec o...

Страница 42: ...to 3rd E V 0 25 5 Ton product X T on motoreducer third product 0 25 5s Toff product X T off motoreducer third product 0 25 5s T Sugar Espresso X T sugar espresso 0 25 5 s T Sugar MB T sugar 0 25 5 s o...

Страница 43: ...product X T on motoreducer second product 0 25 5 s Toff product X T off motoreducer second product 0 25 5 s T product X T 3rd box coupled to 2 E V 0 25 5 s R product X 3rd box delay coupled to 3 E V...

Страница 44: ...he machine will be blocked The microprocessor will read and store the date and time of mains lack When the distribu tor is switched on again when the power is restored the microprocessor will evaluate...

Страница 45: ...e coin box cannot give the change the banknotes will not be accepted 2 Configuration MDB Coin box Cash less Banknote reader The reader is enabled only to recharge keys ON 1 Con guration MDB Coin box B...

Страница 46: ...11 Promotions Menu Enable Promot Enables management of promotions 0 User Set 0 promotions disabled Promo cashless Enables management of promotions with a cahsless system On Off Promo coin Enables mana...

Страница 47: ...on alphanumeric key board Menu enabled only if Promotion Set ON Select key selects promotion key 1 30 Select hot selects hot key 1 30 Select cold 1 selects code 1 A11 B68 Select cold 2 selects code 2...

Страница 48: ...atically reset upon operator passage Dec Powder 1 Decounter value Powder 1 0 1677721s Dec Powder 8 Decounter value Powder 8 0 1677721s The decount value to be entered the Dec Powder X is determined by...

Страница 49: ...ctions 0 16777215 Selections sect 11 Selection counter sector 11 0 65535 Selections sect 68 Selection counter sector 68 0 65535 Free Tot Free Unresettable total free 0 16777215 Tot Free Resettable tot...

Страница 50: ...3 00 00 23 59 Cleaning 4 Sets time of cleaning 4 00 00 23 59 These sections can be set and displayed for the hot machine only 5 3 15 5 Disinfection T disinfection T disinfection 0 120s Disinfection d...

Страница 51: ...ceive e mail messages also with the distributor error The e mail mes sage with the EVA TDS data is sent at the established time and therefore the clock chip is required At the end of this operation th...

Страница 52: ...been stored in the program database The list includes the Number eld specifying the number from which the message was sent corresponding to a speci c distri butor the Date eld specifying date and time...

Страница 53: ...ed eld the major difference lying in the fact that if a data sheet is modi ed with Edit key or a new distributor is added with Add New key the Sale Point and Operator elds will allow you to enter only...

Страница 54: ...distributors stored in the program database the following data will appear type of machine Distributor Customer at which the machine is installed Sale Point and the operator in charge Operator Now yo...

Страница 55: ...unctions which can be enabled by WinBianchi Direct selection keyboard Espresso version In the maintenance mode the keys have the following meaning 01 Group rotation 02 MDB tube lling 03 MDB tube deple...

Страница 56: ...nds Mixer test Switches on the Mixers for 5 sec in the fol lowing order 1 2 3 4 5 6 Group rotation Makes a rotation of the coffee group Alarm scrolling Used to scroll installed alarms and signallings...

Страница 57: ...th the provisions listed below 6 1 3 Daily cleaning recommended The objective is that to avoid the creation of bacteria in the food zone areas For all cleaning operations follow the instructions indic...

Страница 58: ...d on entrust them to specially trained personnel For more complicated interventions such as removing the lime build up in the boilers a good knowledge of the equipment is necessary Monthly effect the...

Страница 59: ...aintenance is in progress it is important that the person responsible for cleaning never has to interrupt his work in order to operate the machine For internal cleaning use clean cloths better if disp...

Страница 60: ...6 4 1 Dosage and grinding regulations Coffee temperature in the cup between 70 and 80 Temperature of soup products in the cup between 70 C and 80 C Grammage of coffee powder between 6 and 8 grams gram...

Страница 61: ...obtain a good rinsing of cups possibly act on the rate screw and then check that doses are reliable Fig 6 11 Automatic adjustment of grinding Fig 6 10 It allows in the expresso versions to keep grind...

Страница 62: ...ispensing group towards outside g 6 13 Then act on the two handles shown in g 6 14 6 16 remove the panel and support it until completely taken out g 6 15 6 17 After carrying out maintenance operations...

Страница 63: ...nt version Disassemble the mixer groups and loosen the three screws shown in gure 6 18 6 19 slide the frontal panel leftwards until the slots are released then remove the panel to access inside Mod 95...

Страница 64: ...onut shells which are charred and activated in oven The activation process gives an exchange surface whose GAC can by alloying organic impurities to it such as disinfectants chlorine and pesticides su...

Страница 65: ...ket can be used The operation can be effected on the distributor as follows switch off the machine turn the lower faucet being careful to put the relative hose in a bucket or better in a drain Fig 6 2...

Страница 66: ...n lamp by carefully taking it out of its support Fig 6 24 After replacing the lamp make sure that it works After cutting off again the power supply of the machine as semble the parts in the reverse or...

Страница 67: ...bed empty the liquid waste bin carefully eliminate the spent grounds bag clean with a cloth all the internal and external surfaces of the machine protect the outisde of the machine with a plastic lm w...

Страница 68: ...his alarm is installed Installer EBI Translator It occurs if the 10 sec timeout lapses during the movement of the spout translator Installer 8 2 2 Non stored alarms EAJ Scale factor This alarm is acti...

Страница 69: ...re credited only in case of instant grinding X 1 or 2 Installer EEK Group It occurs if the programmed coffee group timeout lapses The display will show the Without coffee message The amount is re cre...

Страница 70: ...rs if the value of the FB 1 lter decounter is equal to zero Maintenance operator EEC FB 2 lter It occurs if the value of the FB 2 lter decounter is equal to zero Maintenance operator EEC Esp Filter It...

Страница 71: ...BIANCHI VENDING GROUP S p A Corso Africa 9 24040 Localit Zingonia Verdellino BG ITALIA tel 39 035 419 67 11 fax 39 035 883 304...

Отзывы: