19
Fig. 4.7
Fig. 4.8
4.3 Main Power supply connection
The distributor is predisposed to function with mono-phase 230
Volt tension and is protected with 12,5A and 20A fuses. (10A and
20A for the single boiler and instant versions and 15A and 20A for
the instant hot/cold version).
We suggest to check that:
– the tension of net of 230 V doesn’t have a difference of more
than ± 6%
– The power supply output is able to bear the power load of the
machine.
– use a system of diversifi ed protection
– position the machine in such a way as to ensure that the plug
remains accessible
The machine must be connected to earth in observance with the
current safety norms.
For this reason, verify the plant’s earth wire connection to ascertain
that it is effi cient and it answers national and European safety
electric standards. If necessary require the intervention qualifi ed
personnel for the verifi cation of the plant.
– The distributor is equipped with a power supply cable of H05VV-
F 3x1,5mm², with SCHUKO plug (Fig.4.7).
– The sockets that are not compatible with that of the machine
must be replaced. (Fig.4.8).
– The use of extension, adapters and/ or multiple plugs is forbid-
den.
– In some models, specifi c plugs are assembled for the destination
place.
Bianchi Vending Group spa
declines all responsibility for dama-
ges deriving for the complete or partial failure to observe these
warnings.
Should the power cable be found to be damaged, immediately
disconnect from the power socket.
The power supply cables are to be replaced by skil-
led personnel.