The following items appear at the end of the 16 segment
program in the Secondary Menu.
23. Press the
INDEX
key until
PEnd
appears on the display.
PEnd
is the program’s end action.
•
Hold
keeps the temperature at the present set point.
•
OoFF
turns off the output at the end of the program.
•
LooP
repeats the program starting at
1ti
. If the program is to
repeat, the last segments must return the process to the same
condition when the program started.
•
SP1
reverts to the
SP1
(Primary Menu) value.
The next two menu items can be found in the Primary Menu.
Their appearance will be dependent on which values were
entered in the menu items above.
•
To return to the Primary Menu, wait 30 seconds, or for a faster
response, press the
UP ARROW
and
ENTER
keys followed by
pressing the
DOWN ARROW
and
INDEX
keys.
24. If
StAt
is
On
, three menu items will appear in the Primary
Menu.
•
ti
is the time remaining for the current segment.
•
##ti
is the total time for segment
##
.
•
##SP
is the target set point for segment
##.
2
5
. If
Prog
, in Secondary Menu, is
OFF
, then
Prog
will not appear
in Primary Menu.
P
rog
is the Ramp/Soak Run/Holds function
•
run
means the Ramp/Soak is in operation.
•
OFF
holds the Ramp/Soak program.
26
. Use the
UP ARROW
and
DOWN ARROW
keys to change the
value.
27
. After a value is selected, press
ENTER
to retain that value.
Setting Fuzzy
Logic Parameters