![BFT THALIA Скачать руководство пользователя страница 37](http://html.mh-extra.com/html/bft/thalia/thalia_installation-manual_2746244037.webp)
INSTALLATION MANUAL
Logic
Deinition
Default
Cross out
setting
used
Optional extras
EXPI1
Coniguration of
EXPI1 input on
input-output expan-
sion board.
1-2
1
0
Input conigured as Start E command.
1
Input conigured as Start I command.
2
Input conigured as Open command.
3
Input conigured as Close command.
4
Input conigured as Ped command.
5
Input conigured as Timer command.
6
Input conigured as Timer Pedestrian command.
7
Input conigured as Phot (photocell) safety.
8
Input conigured as Phot op safety (photocell active during opening only).
9
Input conigured as Phot cl safety (photocell active during closing only).
10
Input conigured as Bar safety (safety edge).
11
Input conigured as Phot test safety (tested photocell).
Input 3 (EXPI2) on input/output expansion board is switched automatically to safety device test
input, EXPFAULT1.
12
Input conigured as Phot op test safety (tested photocell active during opening only).
Input 3 (EXPI2) on input/output expansion board is switched automatically to safety device test
input, EXPFAULT1.
13
Input conigured as Phot cl test safety (tested photocell active during closing only).
Input 3 (EXPI2) on input/output expansion board is switched automatically to
safety device test input, EXPFAULT1.
14
Input conigured as Bar safety (tested safety edge).
Input 3 (EXPI2) on input/output expansion board is switched automatically to
safety device test input, EXPFAULT1.
EXPI2
Coniguration of
EXPI2 input
on input-output
expansion board.
1-3
0
0
Input conigured as Start E command.
1
Input conigured as Start I command.
2
Input conigured as Open command.
3
Input conigured as Close command.
4
Input conigured as Ped command.
5
Input conigured as Timer command.
6
Input conigured as Timer Pedestrian command.
7
Input conigured as Phot (photocell) safety.
8
Input conigured as Phot op safety (photocell active during opening only).
9
Input conigured as Phot cl safety (photocell active during closing only).
10
Input conigured as Bar safety (safety edge).
EXPO1
Coniguration of
EXPO2 output
on input-output
expansion board
4-5
9
0
Output conigured as 2
nd
Radio Channel.
1
Output conigured as SCA (gate open light).
2
Output conigured as Courtesy Light command.
3
Output conigured as Zone Light command.
4
Output conigured as Stair Light.
EXPO2
Coniguration of
EXPO2 output
on input-output
expansion board
6-7
9
5
Output conigured as Alarm.
6
Output conigured as Flashing light.
7
Output conigured as Latch.
8
Output conigured as Magnetic lock.
9
Output conigured as Traic Light control with TLB board.
TRAFFIC LIGHT
PREFLASHING
Traic light pre-
lashing
0
0
Pre-lashing switched of.
1
Red lights lash, for 3 seconds, at start of operation.
TRAFFIC LIGHT
RED LAMP
ALWAYS ON
Steadily lit red light
0
0
Red lights of when gate closed.
1
Red lights on when gate closed.
ENGLISH
THALIA
37
D811762 00100_05
Содержание THALIA
Страница 79: ...THALIA 79 D811762 00100_05 ...