TABLE “A” - PARAMETERS MENU - (
.0+
)
Logic
min.
max.
Default
Personal
Definition
Description
RA?
0
180
40
Automatic Closing
Time
Set the numerical value of the automatic closing time from 0 to 180 seconds.
MNCLBCJ?W
RGKC
0,1
100
3
Opening delay time
Set the opening delay time for motor 1 relative to motor 2, between 0,1 and 100
seconds. Adjust the time lag so that the minimum distance between the leaves,
when both are moving, is 50 cm.
AJQBCJ?W
RGKC
0,1
100
3
Closing delay time
Impostare il ritardo di chiusura del motore 2 rispetto al motore 1, regolabile da
0,1 a 100 secondi. Adjust the time lag so that the minimum distance between
the leaves, when both are moving, is 50 cm.
AJC?PR
1
180
40
Time-to-clear traffic
light zone
Set the desired time-to-clear for the zone run through by traffic controlled by the
traffic light, in the range 1 to 180 seconds.
+MRRMPOSC
1%
99%
10%
Motor 1 torque
Set the numerical value of the motor 1 torque between 1% and 99%.
This parameter denotes sensitivity to the obstacle (couple=1 maximum sensitivity).
+MRRMPOSC
1%
99%
10%
Motor 2 torque
Set the numerical value of the motor 1 torque between 1% and 99%.
This parameter denotes sensitivity to the obstacle (couple=1 maximum sensitivity).
QJMTQNCCB
0%
99%
20%
Slow-down speed
Imposta la percentuale della velocità di rallentamento tra 0% e 99% della velocità
normale.
N.B. il valore 0 non effettua il rallentamento dei motori.
BGQRQJMSB
1%
99%
20%
Slow-down space
Set the slow-down percentage between 1% and 99% with respect to the com-
plete manoeuvre.
?NN?PX
1%
99%
50%
Pedestrian opening
Set the partial opening percentage for motor 2.
XMLC
0
129
0
Zone
Set the zone number between a minimum value of 0 and a maximum value of
129.
The zone number allows you to create groups of automated devices, each of which
answers to the Zone Master. Each zone can have only one Master. The Master of
zone 0 also controls the Masters and Slaves of the other zones.
TABLE “B” - LOGIC MENU - (
JMEGA
)
Logic
Default Definition
Cross out
setting
used
Description
RA?
OFF
Automatic Closing
Time
ON
Activates automatic closing
OFF
Excludes automatic closing
'@JMNCL
OFF
Opening Impulse lock
ON
The Start impulse has no effect during the opening phase.
OFF
The Start impulse becomes effective during the opening phase.
G@J2!
OFF
Impulse lock TCA
ON
The Start impulse has no effect during the TCA dwell period.
OFF
The Start impulse becomes effective during the TCA dwell period.
G@JAJMQC
OFF
Impulse lock on closing
ON
The start impulse has no effect during the closing stage.
OFF
The start impulse is effective during the closing stage.
P?K@JMUAMN
OFF
Ram blow on opening
ON
It pushes for approx. 2 seconds in closing direction before opening. This allows the electric
lock to be released more easily.
IMPORTANT -
When no adequate mechanical backstops are installed, do not use this function.
OFF
Excludes the ram blow in closing.
P?K@JMUAAJ
OFF
Ram blow in closing
ON
Before closing completely, the gate pushes for approx. 2 seconds as it opens. This allows
the solenoid lock to be released more easily.
IMPORTANT -
When no adequate mechanical backstops are installed, do not use this function.
OFF
Excludes the ram blow in closing.
QRCN
OFF
2-step, 4-step logic
ON
Enables 2-step logic (prevails over “3-step logic”).
OFF
Enables 4-step logic when the 3-step logic is set to OFF.
QRCN
OFF
3-step logic
ON
Enables 2-step logic
(prevails over “3-step
logic”).
A start impulse has the following effects:
2 steps
3 steps
4 steps
closed
opens
opens
opens
on closing
stop
open
closes
closes
closes
on opening
stop + TCA
stop + TCA
after stop
opens
opens
opens
OFF
Enables 4-step logic
when the 3-step logic
is set to OFF.
NPC?J?P+
OFF
Pre alarm
ON
The blinker comes on about 3 seconds before the motor starts.
OFF
The blinker comes on at the same time as the motor starts.