Parameter Description
Default
(IM...)
Default
(IR...)
min MAX
S10
Defrost type started through keyboard:
0= electrical or due to compressor stop
1= hot gas
2= air
0 0
0
2
CONFIGURATION
C01
Door input (0 de-activated; 1 activated)
1
1
0
1
C02
Door open polarity
0
0
0
1
C03
Door open alarm delay
2 min
2 min
0 min 60 min
C04
Activates buzzer (0 de-activated; 1 activated)
1
1
0
1
C05
Buzzer duration at the end of quick cooling cycle
10 sec
10 sec
0
600 sec
C06
Temperature difference in the first phase of needle insertion
test (0 = test excluded)
45°F 45°F 0
140°F
C07
Duration of the second phase of needle insertion test (0=test
excluded)
56 sec
56 sec
0
600 sec
C08
Activates condenser probe
0 = no probe
1 = probe
1
1
0
1
C09
Compressor stop delay due to door opening
30 sec
30 sec
0 sec
60 sec
C10
Pressostat alarm detection time
5 sec
5 sec
0 sec
60 sec
C11
High pressare digital input polarity
0
0
0
1
C12
Resistances starting SetPoint
23°F
23°F
14°F
68°F
ADJUSTMENT
R01
Compressor start/stop hysteresis
38°F
38°F
32°F
68°F
R02
Min. interval between 2 compressor starting
2 min
2 min
0 min 30 min
R03
Compressor start delay from card activation
0 sec
0 sec
0 sec 300 sec
R04
Compressor Duty-Cycle time with faulty room probe in storing
10 min
10 min
0 min 90 min
R05
Compressor ON time faulty room in pos. storing
3 min
3 min
0 min 90 min
R06
Compressor ON time with faulty room in neg. storing
8 min
8 min
0 min 90 min
R07
Needle min. temperature for starting quick cooling
158°F
158°F
32°F
194°F
R08
Compressor inhibition temperature
194°F
194°F
32°F
212°F
R09
Compressor Protection function activation time
24 ore
24 ore
0 ore 240 ore
R10
Pulse duration
2 sec
2 sec
1 sec
10 sec
R11
Pause between pulses
4 sec
4 sec
1 sec
10 sec
R12
Number of pulses
3
3
1
20
FANS
F01
Evaporator fans activation hysteresis
36°F
36°F
32°F 68°F
F02
Condenser fans activation hysteresis
36°F
36°F
32°F 68°F
F03
Evaporator fans activation SetPoint
41°F
41°F
-58°F
122°F
F04
Condenser fans activation SetPoint
59°F
59°F
-58°F
122°F
F05
Evaporator fans during defrost
0 = fans OFF; 1 = fans ON
0 0
0
1
F06
Condenser fans during defrost
0 = fans OFF; 1 = fans ON
0 0
0
1
F07
Fans stop time after defrost
1 min
1 min
0 min 30 min
F08
Condenser fans stop delay
30 sec
30 sec
0 sec 300 sec
F09
Evaporator fans control during quick cooling:
0 = fans always ON
1 = fans thermostated by evaporator temperature
0 0
0
1
F10
Evaporator fans control during storing:
0 = fans in parallel with the compressor
1 = fans thermostated by evaporator temperature
0 0
0
1
F11
Evaporator fans inhibition temperature
158°F
158°F
32°F
194°F
PR1
Sampling time
10 min
10 min
1 min 60 min