Use the keys up e down to select the new value of the parameter
Press enter to confirm your choice
Press menu several times to exit
DESCRIPTION OF PARAMETERS
Parameter Description
Default
(IM...)
Default
(IR...)
min MAX
POSITIVE QUICK COOLING
P01
Room SetPoint in pos. quick cooling, Soft phase
23°F
23°F
-22°F
86°F
P02
SetPoint cella in abbattimento Hard
-13°F
-13°F
-40°F
86°F
P03
Needle SetPoint in pos. quick cooling , Soft phase
38°F
38°F
-22°F
86°F
P04
Needle SetPoint in Hard quick coolong
68°F
68°F
-22°F
86°F
P05
Positive quick cooling duration
90min
90min
0min 900min
P06
Hard phase duration expressed as % in relation to P05
60%
60%
0%
100%
P07
Room SetPoint in pos. storing
36°F
36°F
-22°F
86°F
NEGATIVE QUICK COOLING
N01
Room SetPoint in neg, quick cooling
-13°F
-13°F
-40°F
86°F
N02
Needle SetPoint in neg. quick cooling
-0°F
-0°F
-22°F
86°F
N03
Negative quick cooling duration
240min
240min
0min 900min
N04
Room SetPoint in neg. storing
-8°F
-8°F
-40°F
86°F
ALARMS
A01
Temperature alarm hysteresis
36°F
36°F
32°F
122°F
A02
High temperature limit alarm in pos. storing in relation to P07 50°F 50°F 32°F
122°F
A03
Low temperature limit alarm in pos. storing in relation to P07 14°F 14°F -58°F
32°F
A04
High temperature limit alarm in neg. storing in relation to N04 50°F
50°F 32°F
122°F
A05
Low temperature limit alarm in neg. storing in relation to N04 14°F 14°F -58°F
32°F
A06
Temperature alarm delay fron storing or defrost start
60min
60min
0min 300min
A07
Temperature alarm delay
30min
30min
0min 300min
A08
Duration of the buzzer in the alarm mode
1min
1min
0min 240min
DISPLAY
D01
Temperature unit of measurement (0 Celsius; 1 Fahrenheit)
0
0
0
1
D02
Room probe Offset
32°F
32°F
14°F
50°F
D03
BackLight (0 on when pressing a key; 1 always on)
0
0
0
1
DEFROST
S01
Performs defrost on quick cooling start
0 = No; 1 = Yes
0 0
0
1
S02
End-of-defrost temperature
47°F
47°F
14°F
86°F
S03
Defrost max. duration
15 min
15 min
1 min 90 min
S04
Interval between defrosts in storing (0=excluded)
0 ore
0 ore
0
18 ore
S05
Type of defrost:
0= electrical or due to compressor stop
1= hot gas
2= air
2 2
0
2
S06
Dripping time
1 min
1 min
0 min 90 min
S07
Compressor activation delay with hot gas defrost
0 sec
0 sec
0 sec 600 sec
S08
First defrost activation time from storing start (0=excluded)
0
0
0
90 min
S09
Ignores compressor protection delays in defrost
0
0
0
1