10. Power Supply
1. Power source must be 240 VAC. Connect the power supply cable
on to the connectors of the main switch.
Cable coming from the main board to the gate, must be secured
according legislations for electrical installations applicable at that
time.
Use a low voltage power solid cable with a section according to the table underneath. (For
example : NYY JZ 3 x 2,5mm2 according to VDE0276 part 603, VDE 0271 and IEC 52)
Section
(mm
2
) Maximum
distance
(m)
2,5
300
4
600
6
900
2. Switch the current on by turning the main switch in position “ON”.
WARNING:
THE CALUCULATIONS ARE DONE ON OUR GATE WITH ALL
OUR POSSIBLE ACCESSORIES. IF YOU ARE CONNECTING
MORE CONSUMERS TO IT, IT MAY BE NECESSARY TO USE
A BIGGER SECTION.
11. Adjustment and testing safety equipment:
11.1 Induction system
Check if the jumpers (J1 and J2) for connecting the stationary coil to
the decoder board are connected. Check if parameter B is set on ‘1’.
11.2 Safety Strips
Check if all safety strips are functioning correctly.
When the safety strip on the top of the wing is activated an “Sc”
indication must appear on the display of the controller board.
An “So” indication must appear when the safety strip at the rear of the
wing is activated.
“So” must be indicated when a safety strips, on the guiding post, in the
free passage of the gate is activated.
“Sc” must be indicated when a safety strips, on the guiding post, at the
closing side of the gate is activated.