NORMAL STARTING AND STOPPING
{
PSM720 PUSH BUTTON START & STOP
PROTECTION MODULE - FUNCTIONALITY
Turn on the starter battery isolation switch.
1 Press the green ‘
RUN/START
’ button momentarily.
Red panel light for DC `power on` should
illuminate.
Starter battery alternator not charging should
illuminate.
Low engine oil pressure light will illuminate
but the protection hold timer over rides this
engine fault protection circuit on start up for
18 seconds after initial firing.
High engine temperature light will not
illuminate.
Glow plug light will illuminate, for the
duration of the programmed pre heat time -
10 seconds The engine will not start until the
glow plugs have been fully pre heated and
the light stops illuminating
Depending on the engine model the warning
light may flash during the glow plug pre heat
duration.
2 When the glow plug light stops illuminating.
Press and hold the green button for
no
more than 9 seconds
to start the engine.
When the engine cranks and then fi res,
release the green button to disengage the
starter motor. If the green button is pressed
and the starter is operated for
10 seconds
,
the module will shut down on overcrank
fault protection and the warning light will
illuminate.
3 Once the engine has run up to operating speed, the
engine protection hold off timer will countdown from
18 seconds, once done all engine fault protection
circuits become live. All lights except DC on should stop
illuminating. In the event of a engine protection fault
the appropriate light will illuminate and the engine will
shut down.
4 If the engine does not start after initial
9 seconds
,
wait
20 seconds
before re-attempting start by pushing
in the green button for no more than
9 seconds
.
5 Pressing the red ‘
STOP/RESET
’ button will shut down
the engine if running or reset the module and fault
protection circuits if already stopped. Should the engine
not start after 3 attempts, press the red button for the
module to operate all fault protection shutdowns and
reset. Then repeat step 1 & 2.
Engine Shut Down Fault Protection
The generating set will automatically shut down for the
following fault protection circuits.
Low Engine
High Engine
Oil Pressure
Temperature
Engine Fault Warning
The generating set will not automatically shut down for
the following engine fault warning.
DC Alternator
charge fail
WARNING!
THE STARTER MOTOR WINDINGS CAN BE BURNT OUT WITH CONTINUOUS CRANKING.
Содержание BetaGen 10
Страница 13: ...11...
Страница 90: ...88...
Страница 91: ...89...
Страница 92: ...90...
Страница 93: ...91...
Страница 94: ...92...
Страница 95: ...93...
Страница 96: ...94...
Страница 97: ...95...
Страница 98: ...96...
Страница 99: ...97...
Страница 100: ...98...
Страница 101: ...99...
Страница 102: ...100...
Страница 103: ...101...
Страница 106: ...104 Notes...
Страница 107: ...105 Notes...
Страница 113: ...111 Service Date Responsible 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32...
Страница 114: ...112 Service Date Responsible 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48...
Страница 115: ...Service Date Responsible 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64...