background image

Page 2/13

6W-5826

09-2012

IR motion detector comfort

3.  Function

Correct use

 

Automatic switching of lighting depending on heat motion and ambient brightness

 

Application module for switch insert, flush-mounted dimmer or motion detector extension 

unit

 

Only suitable for use in indoor areas with no drip and no spray water.

Product characteristics

 

Integrated button for selecting operating modes and special functions 

 

Lockable integrated button

 

Operating mode - automatic mode, permanent ON, permanent OFF can be selected

 

Display operating mode via LED

 

Potentiometer for adjusting the response brightness, delay time and detection sensitivity 

 

Delay time adjustable

 

Pulse encoder mode for current pulse/stairwell circuits

 

Adjustable detection angle for adaptation of the detection area

 

Additional adjustment of the response brightness via Teach-In function

 

Party function

 

Presence simulation

 

Operation on motion detector extension units

 

Optional extension unit operation via installation button 

 

Start-up via IR hand-held transmitter

Automatic mode

The motion detector detects heat motion caused by people, animals, or objects.
Applied on switch insert:

 

The light will be switched on for the delay time, if movements are detected in the detection 

area and the set brightness threshold is undershot. Each detected movement restarts the 

delay time.

 

The light will be switched off if no additional movements are detected in the detection area 

and the set delay time has elapsed.

On flush-mounted dimmer:

 

The light will be switched on to the switch-on brightness level for the delay time if 

movements are detected in the detection area and the set brightness threshold is 

undershot. Each detected movement restarts the delay time.

 

After the delay time elapses the lighting will be dimmed to 50% of the switch-on brightness-

level and will remain at this brightness level for 30 s (switch-off pre-warning). Each 

movement detected during the switch-off pre-warning restarts the delay time and restores 

the switch-on brightness level.

 

The light will be switched off if no motion is detected any longer in the detection area and 

the set delay time and the switch-off time have elapsed.

On extension unit

 

If motion is detected in the detection area of the extension unit, the extension unit insert 

sends a pulse to the main unit and then locks for 10 seconds. Recording takes place in

-

dependently of the brightness on the extension unit. If motion is still detected after 10 se

-

conds, a pulse is sent again.

 

Upon receiving an extension unit pulse, the main unit switches the light on for the delay 

time, if the set brightness threshold is undershot. Every further extension unit pulse restarts 

the delay time of the main unit.

Performance after mains breakdown/return of mains supply

 

Mains breakdown shorter than 0.2 s: 

Содержание 8534 12 series

Страница 1: ...comply with these installation instructions may result in damage to the device fire or other hazards Due to its detection behaviour the device is not suitable for use in burglary detection or alarm sy...

Страница 2: ...detected movement restarts the delay time The light will be switched off if no additional movements are detected in the detection area and the set delay time has elapsed On flush mounted dimmer The li...

Страница 3: ...ecuted by pushing the button 7 on the motion detector A short press of the button switches the operating modes The operating mode is displayed via the status LED behind the optics cover of the motion...

Страница 4: ...ched on via a mechanical push button extension unit For extension unit operation the lighting is switched on independently of the set brightness threshold When using the flush mounted dimmers the last...

Страница 5: ...ts the current ambient brightness and saves it as response brightness Setting of the response brightness via Teach In function and via the brightness potentiome ter has the same priority Teach In over...

Страница 6: ...30 s and changes to switching dimming ope ration Energy saving lamps are switched ON at a brightness level of at least 50 brightness in order to ensure an ignition process 4 x 230 V LED lamp universal...

Страница 7: ...ule via the in terface between application and power module 6 As soon as voltage is supplied to the application module the status LED indicates the com patibility to the insert used Status LED display...

Страница 8: ...e brightness potentiometer Setting the detection area 1 75 m 1 1 m 8 m 8 m 180 2 m 4 m 6 m 8 m 10 m 12 m Figure 6 detection area of the motion detector for mounting height 1 1 m 2 m 6 m 6 m 4 m 6 m 8...

Страница 9: ...n area using a detection test and adjust if necessary If the detection area is too small it can be extended via motion detector extension units Setting the response brightness The response brightness...

Страница 10: ...the sensitivity Detection is factory set to maximum sensitivity If there are frequent incorrect detections the sensitivity can be reduced Turn the sensitivity potentiometer Fig 5 9 to the desired posi...

Страница 11: ...ction for the motion detector is locked via the Motion and brightness dependent switching on switching off of the load Activate the presence simulation Activate permanent OFF Activate permanent ON 16...

Страница 12: ...to control other motion detectors Briefly press the button on the hand held transmitter The controlled motion detector does not accept any further setting commands Briefly press the button on the hand...

Страница 13: ...mal changes to the product in the interest of tech nical progress Our products are under guarantee within the scope of the statutory provisions If you have a warranty claim please contact the point of...

Отзывы: