Page 7/13
6W-5826
09-2012
IR motion detector comfort
180°
ç
ç
1,10 m
2,2 m
Fig 4: Installation location of the motion detectors
Assembly of the device (Figure 1)
Information on electrical connection are to be taken from the operating instruction of for the
insert.
Attach the bottom part of the application module (3) together with frame (2) to a suitable
insert (1) and establish a connection between insert and the application module via the in
-
terface between application and power module (6).
As soon as voltage is supplied to the application module, the status LED indicates the com
-
patibility to the insert used.
Status LED display
Meaning
LED blinks green (approx.
5 s until motion detection is
active)
Compatible
LED blinks red for 5 s
Not compatible
If available, fix dismantling protection with screw (5).
After start-up, click the design cover (4) into place on the application module (3).
If start-up is to take place using a hand-held transmitter, set the response brightness poten-
tiometer (Figure 5, 13) to the T position and then snap on the design cover.