6W-5826

09-2012

IR motion detector comfort

The function is not impaired.

 

Mains breakdown longer than 0.2 s: 

There is no function during the mains breakdown. The current configuration is saved in 

non-volatile memory.

 

Return of mains supply:  

The application module executes an initialisation for approx. 15 s, during which the lighting 

will be switched on. Motion detection starts thereafter. If no motion is detected during the 

first 5 s, the lighting is switched off. The saved configuration is loaded from memory. During 

this period local operation via the button or extension unit can be used. 

4.  Operation

Operating concept

(8)

(7)

Fig. 2: Operating and display elements

(7)  Button
(8)  Status LED
Operation is executed by pushing the button (7) on the motion detector:

 

A short press of the button switches the operating modes. The operating mode is displayed 

via the status LED behind the optics cover of the motion detector. 

 

Keeping the button pressed activates special functions. Selection of the special functions is 

supported by the LED display (Fig. 3).

Function 

Party function

Teach-In

Keylock

Presence 

simulation

Load setting 

mode

LED display

Hold time 

operation 

button

> 5 s

> 10 s

> 15 s

> 20 s 

> 25 s

1)

 

Only on universal switch insert and universal flush-mounted dimmer

Fig. 3: Selection of the special functions and LED display

Selecting the operating mode

 

Briefly press the button repeatedly until the desired operating mode is selected.

The status LED indicates the selected operating mode (see Table 1).

  Switching the operating mode finishes the party function or presence simulation, if these 

functions were previously active.

Содержание 8534 12 series

Страница 1: ...comply with these installation instructions may result in damage to the device fire or other hazards Due to its detection behaviour the device is not suitable for use in burglary detection or alarm sy...

Страница 2: ...detected movement restarts the delay time The light will be switched off if no additional movements are detected in the detection area and the set delay time has elapsed On flush mounted dimmer The li...

Страница 3: ...ecuted by pushing the button 7 on the motion detector A short press of the button switches the operating modes The operating mode is displayed via the status LED behind the optics cover of the motion...

Страница 4: ...ched on via a mechanical push button extension unit For extension unit operation the lighting is switched on independently of the set brightness threshold When using the flush mounted dimmers the last...

Страница 5: ...ts the current ambient brightness and saves it as response brightness Setting of the response brightness via Teach In function and via the brightness potentiome ter has the same priority Teach In over...

Страница 6: ...30 s and changes to switching dimming ope ration Energy saving lamps are switched ON at a brightness level of at least 50 brightness in order to ensure an ignition process 4 x 230 V LED lamp universal...

Страница 7: ...ule via the in terface between application and power module 6 As soon as voltage is supplied to the application module the status LED indicates the com patibility to the insert used Status LED display...

Страница 8: ...e brightness potentiometer Setting the detection area 1 75 m 1 1 m 8 m 8 m 180 2 m 4 m 6 m 8 m 10 m 12 m Figure 6 detection area of the motion detector for mounting height 1 1 m 2 m 6 m 6 m 4 m 6 m 8...

Страница 9: ...n area using a detection test and adjust if necessary If the detection area is too small it can be extended via motion detector extension units Setting the response brightness The response brightness...

Страница 10: ...the sensitivity Detection is factory set to maximum sensitivity If there are frequent incorrect detections the sensitivity can be reduced Turn the sensitivity potentiometer Fig 5 9 to the desired posi...

Страница 11: ...ction for the motion detector is locked via the Motion and brightness dependent switching on switching off of the load Activate the presence simulation Activate permanent OFF Activate permanent ON 16...

Страница 12: ...to control other motion detectors Briefly press the button on the hand held transmitter The controlled motion detector does not accept any further setting commands Briefly press the button on the hand...

Страница 13: ...mal changes to the product in the interest of tech nical progress Our products are under guarantee within the scope of the statutory provisions If you have a warranty claim please contact the point of...

Отзывы: