![Beretta EXCLUSIVE X Скачать руководство пользователя страница 30](http://html1.mh-extra.com/html/beretta/exclusive-x/exclusive-x_installer-and-user-manual_2736624030.webp)
EXCLUSIVE X
30
ADDED DEVICE
Class
Bonus
EXTERNAL PROBE
II
2%
OT CONTROL PANEL* (°)
V
3%
EXTERNAL PROBE + OT CONTROL PANEL*
VI
4%
NOTE
(if connected to the boiler the external probe or OT remote control or both devices):
With reference to Delegated Regulation (EU) No. 811/2013, the data in the table can be used for completing the product card and the labelling for ambient heating appliances, for mixed
heating appliances, for assemblies of appliances for ambient heating, and for temperature control devices and solar devices:
(*) Set as room thermostat - (°) Factory supplied configuration
16 ErP
DATA
Parameter
Symbol
EXCLUSIVE X
25C
EXCLUSIVE X
30C
EXCLUSIVE X
35C
EXCLUSIVE X
40C
Unit
Seasonal space heating energy efficiency class
-
A
A
A
A
-
Water heating energy efficiency class
-
A
A
A
A
-
Rated heat output
Pnominal
20
24
31
31
kW
Seasonal space heating energy efficiency
ηs
93
94
94
94
%
Useful heat output
At rated heat output and high-temperature regime (*)
P4
19,5
24,4
31,2
31,2
kW
At 30% of rated heat output and low-temperature regime (**)
P1
6,5
8,2
10,5
10,5
kW
Useful efficiency
At rated heat output and high-temperature regime (*)
η4
87,8
88,0
87,9
87,9
%
At 30% of rated heat output and low-temperature regime (**)
η1
98,3
98,6
98,6
98,6
%
Auxiliary electricity consumption
At full load
elmax
27,0
32,0
49,0
49,0
W
At part load
elmin
13,0
13,0
13,0
13,0
W
In Stand-by mode
PSB
3,0
3,0
3,0
3,0
W
Other parameters
Stand-by heat loss
Pstby
30,2
26,0
26,0
26,0
W
Pilot flame energy consumption
Pign
-
-
-
-
W
Annual energy consumption
QHE
60
75
96
96
GJ
Sound power level, indoors
LWA
50
50
54
54
dB
Emissions of nitrogen oxides
NOx
46
35
38
38
mg/kWh
For combination heaters
Declared load profile
XL
XL
XL
XL
Water heating energy efficiency
ηwh
86
85
85
85
%
Daily electricity consumption
Qelec
0,155
0,141
0,157
0,157
kWh
Daily fuel consumption
Qfuel
22,482
22,942
22,986
22,986
kWh
Annual electricity consumption
AEC
34
31
34
34
kWh
Annual fuel consumption
AFC
17
17
17
17
GJ
(*) High-temperature regime means 60 °C return temperature at heater inlet and 80 °C feed temperature at heater outlet.
(**) Low temperature means for condensing boilers 30 °C, for low-temperature boilers 37 °C and for other heaters 50 °C return temperature (at heater inlet).