9
8
ENGLISH
QUADRA GREEN 25 R.S.I.
The boiler continues to operate until the temperatures set on the boiler are
reached, or the heat request is met; after which it goes back on standby.
If the red LED indicator near
the
sy
mbol (fig. 33) on the control panel
lights up, this means the boiler is in temporary shutdown status (see chap-
ter “Light signals and faults”).
The digital monitor indicates the fault code detected.
Automatic Temperature Control System function (S.A.R.A.) fig. 34
Setting the heating water temperature selector to the area marked “AUTO”
(temperature range 55 to 65°C), activates the automatic temperature con-
trol system (frequency 0.1 sec. on; then 0.1 sec. off; for 0.5 seconds): ac-
cording to the temperature set on the room thermostat and the time taken
to reach it, the boiler varies automatically the heating water temperature
reducing the operating time, allowing greater ease of operation and energy
saving. On the control panel, the green LED flashes ON for 0.5 seconds,
OFF for 3.5 seconds.
Reset function
To restore operation, set the function selector to
(fig. 31), wait 5-6 sec
-
onds then set the function selector to the required position, checking that
the red indicator light is OFF.
At this point the boiler will automatically start and the red lamp switches on
in green.
NOTE:
If the attempt to reset the appliance does not activate operation,
contact the Technical Assistance Service.
4.2 Switching off
Temporary switch-off
In case of absence for short periods of time, set the mode selector (fig.
31) to (OFF).
In this way (leaving the electricity and fuel supplies enabled), the boiler is
protected by the following systems:
Anti-frost device:
when the temperature of the water in the boiler falls
below 5°C, the circulator and, if necessary, the burner are activated at mini-
mum output levels to bring the water temperature back to the values for
safety (35°C). During the anti-frost cycle, the symbol
(fig. 35) appears
on the digital monitor.
Circulator anti-blocking function:
an operation cycle is activated every
24 hours.
DHW Antifreeze
(only when connected to an external storage tank with
probe): the function is activated if the temperature measured by the storage
tank probe drops below 5° C. A heat request is generated in this phase with
the ignition of the burner at minimum power, which is maintained until the
water temperature reaches 55° C. During the anti-frost cycle, the symbol
(fig. 35) appears on the digital monitor.
Switching off for long periods
In case of absence for long periods of time, set the mode selector (fig. 31) to
(OFF). Turn the main system switch OFF. Close the fuel and water taps
of the heating and domestic hot water system. In this case, anti-frost device
is deactivated: drain the systems, in case of risk of frost.
BOILER STATUS
DISPLAY
RED LED
YELLOW LED
GREEN LED
TYPES OF
ALARMS
Off status (OFF)
OFF
flashing 0.5 on/
3.5 off
None
Stand-by
-
flashing 0.5 on/
3.5 off
Signal
ACF alarm lockout module
A01
on
Definitive lockout
ACF electronics fault alarm
Fumes exhaust - air intake obstruction alarm
Limit thermostat alarm
A02
flashing 0.5 on/
0.5 off
Definitive lockout
Tacho fan alarm
A03
on
Definitive lockout
Water pressure switch alarm
A04
on
on
Definitive lockout
NTC domestic water fault (only when con-
nected to an external storage tank with probe)
A06
flashing 0.5 on/
0.5 off
flashing 0.5 on/
0.5 off
Signal
NTC heating outlet fault
A07
on
Temporary stop
Heating outlet probe overtemperature
Temporary then
definitive
Outlet/return line probe differential alarm
Definitive lockout
NTC heating return line fault
A08
on
Temporary stop
Heating return line probe overtemperature
Temporary then
definitive
Outlet/return line probe differential alarm
Definitive lockout
Cleaning the primary heat exchanger
A09
flashing 0.5 on/
0.5 off
flashing 0.5 on/
0.5 off
Signal
NTC flue gases fault
Temporary stop
Flue gases probe overtemperature
on
Definitive lockout
False flame
A11
flashing 0.2 on/
0.2 off
Temporary stop
Low temperature system thermostat alarm
A77
on
Temporary stop
Temporary pending ignition
flashing 0.5 on/
0.5 off
Temporary stop
Water pressure switch intervention
flashing 0.5 on/
0.5 off
Temporary stop
Calibration service
ADJ
flashing 0.5 on/
0.5 off
flashing 0.5 on/0.5
off
flashing 0.5 on/
0.5 off
Signal
Calibration installer
Chimney sweep
ACO
flashing 0.5 on/0.5
off
Signal
Vent cycle
flashing 0.5 on/
1.0 off
flashing 0.5 on/1.0
off
flashing 0.5 on/
1.0 off
Signal
External probe presence
Signal
Domestic water heat request
60
°C
Signal
Heating heat request
80
°C
Signal
Antifreeze heat request
Signal
Flame present
on
Signal