22
Maintenance
WARNING
To avoid personal injury, always shut OFF the main power supply and
disconnects to the compressor, relive all air pressure from the system,
and check electrical system with electrical probe before starting any
service or maintenance on the compressor.
maintenance
DAILY:
Drain the Receiver- condensation will accumulate in the tank daily, and
should be drained at least once a day. This is done to reduce corrosions
of the tank from the inside. Always wear protective eyewear when
draining the tank.
Check Airend Oil Level- remove oil fill cap and check for proper level. Oil
should be half way up the at the bottom or half way up the threads on
the oil fill
Check Oil Cooler: check cooler for proper air flow to keep unit cool clean
if necessary
Check unit for any unusual noise or vibrations
WEEKLY:
Clean air filter: this will ensure that no dirt or heavy particulate makes its
way into the compressors valve assemblies.
Clean external parts of compressor and electric motor: this helps to
ensure proper cooling and prevents rust and corrosion on critical parts
Check safety Valves: this is don’t to ensure they are not stuck in place
and operating properly
Elite Units
Check auto tank drain for proper function
MONTHLY:
Inspect complete air system for leaks: this is done to make sure the
compressor does not get out of its duty cycle due to air leak in the
system
Inspect Oil for Contamination: this is done to ensure that harmful
deposits do not build up in the oil.
Check belt tension: this is done to ensure the belt do not fail pre-
maturely, tighten them as needed to ensure they do not slip. If belts are
loose, tighten per instructions on next page. Failure to tighten can cause
pre-mature belt failure.