18
Stopping for Maintenance or Service
The following procedure should be followed to maximize safety when
preparing for maintenance or service.
1. Disconnect and lock-out the main power switch and hang a sign at the
switch Informing of the unit being serviced.
2. Close shut-off valve (block valve) between receiver and compressor,
or receiver and Plant air system, to prevent any back-up of air flow into
the area to be serviced.
3. Lock open manual vent valve and wait for the pressure in the area
to be serviced (compressor, receiver, etc.) to be completely relieved
before starting service. The Manual vent valve may be the drain valve in
the receiver. NEVER remove a plug to relieve the pressure.
4. Open all manual drain valves within the area to be serviced.
5. Wait for the unit to cool before starting service, (temperatures at 125
degrees F can burn the skin), some surface temperatures exceed 400
degrees F when the compressor is working).
6. Clean up all oils spills immediately to prevent slipping.
stopping
procedure
CAUTION
Never assume the compressor is ready for maintenance or service
because it is stopped. The automatic stop-start control may start the
compressor at any time!