continued
Troubleshooting
until the contacts snap in
place. Replace the orange
wedge-lock, reconnect the
actuator to the extension cable
and retest.
• Problem: Actuator extends when
BOW UP Button is pressed and
actuator retracts when BOW
DOWN is pressed.
»
The actuator wires are
reversed in the connector.
Disconnect the actuator that
is not moving properly.
Remove the orange wedge-
lock from the connector.
Remove the contacts from
the connector using a small
straight blade screw driver
to release the internal snaps.
Re-insert the actuator wires
into the connector in the
reverse order. Re-insert the
orange wedge-lock into the
connector. Reconnect the
actuator to the extension cable
and re-test.
• Problem: The port (left) Actuator
extends when the port (left) BOW
DOWN button is pressed and stbd.
(right) actuator extends when stbd.
(right) BOW DOWN button is
pressed.
»
The actuators are reversed.
Unplug the actuators at the
extension cable and switch
the connections between
the extension cables and the
actuators.
• Problem: One or two of the upper
yellow LEDs on the control is
flashing
»
The system did not detect an
actuator on the side that is
flashing
»
Check to insure that the
actuators are plugged into
the extension cables, and the
extension cables are plugged
into the relay module.
»
On the actuator that is not
moving, disconnect the
actuator from the cable.
Remove the orange wedge-
lock from the connector
and inspect the connector
contacts. The contact must
be seated evenly and all the
way up to the end of the
connector for the mating pins
to make contact. Push the
wires up into the connector
until the contacts snap in
place. Replace the orange
wedge-lock, reconnect the
actuator to the extension cable
and retest.
If the actuators still do not operate
after following any of the steps above
- STOP and call Bennett for further
assistance at (954) 427-1400, Monday
through Friday, 8:00 a.m. to 5:00
Bennett Marine
| Bolt Electric Trim Tab System
37