If dosing is not interrupted for 240 min or 4 hours, the unit goes into alarm mode and stops
the functionality of the dosing pumps and electrolysis.
Alarm OFF:
Never operate the unit in alarm OFF mode during normal and automatic operation. Alarm
OFF mode is only used to monitor your unit in case of a malfunction. If you set the alarm to
off, the alarm will not operate for 60 min.
Suction cap of pH in the acid canister. It is recommended that the suction cap not be
lowered to the bottom of the canister. If something should go wrong with the dosage, the
whole canister of acid will not be pumped into the pool.
12) How much salt should be put in the pool?
Although the equipment starts to work with smaller salt percentage, it reaches optimum of
salt with concentrations with 2-2,5 kg/m3. We recommend a concentration of 2.5kg/m3 to
compensate for small losses of salt that occur during filter cleaning, the effect of rainfall etc.
To calculate the salt to be added, multiply the total volume in m3 of your pool x2.5
Example:
A pool with the following dimensions: Length 9m ; 4.5m in width and 1.6 m depth
9 x 4.5 x 1.6 = 64.8 cubic meters. 64.8 x 2.5 = 162 kg salt to be added
13) Installing the Suction Cup
Insert the suction nipple from Ph into the acid canister. It is recommended that the suction
cap not be lowered to the bottom of the canister. If something should go wrong with the
dosage, the entire canister of acid will not be pumped into the pool.
14) Start the installation
Start the installation by turning on the pump's electricity until the salt is dissolved and
homogeneously distributed in the pool water.
Verify the pH, and adjust the pH to 7.2-7.4.
15 ) Start salt electrolysis and pH dosing.
Calibration and verification of chlorine /Ph
The correctness of pH and Chlorine should be verified regularly (weekly) by a proper
measurement with color (e.g. Poollab ZWMX1060).
Every installation should be calibrated at least once a year. In case of a long swimming
season, or in case of deviation between color method measurement and pH/Rx values, it is
recommended to also calibrate every six months, so twice a year.
The procedure calibration and setpoint adjustment have already been described in detail
above.
Connecting a flow switch