CC613_D00381_04_M_XXEN/11.2020 9
CC613 charge controller
i
The charge controller with residual direct current monitoring module (RDC-M) only works in combination
with the measuring current transformer (to be ordered separately).
I
C
aution
!
Risk of damage when pulling out the measuring current
transformer plug!
If the measuring current transformer plug is pulled out
using too much force, the enclosure and the internal components may be
damaged. Use needle-nose pliers to unlock the measuring current transfor-
mer plug.
2.4.2 Load current and cooling control
(temperature monitoring)
The charge controller is equipped with a temperature sensor, which allows the temperature in the environ-
ment of the charge controller to be estimated. Based on this estimation it is possible to dynamically reduce
the charging current or even suspend charging. This feature can serve to maintain the temperature inside the
enclosure within the permissible range for the components used in a charging system. Two temperature
thresholds for charging current reduction and charging interruption can be set via the
Manufacturer
tab.
i
The actual temperature is affected by heat generated by the controller itself.