![Bender CC613 Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/bender/cc613/cc613_manual_2731541018.webp)
18 CC613_D00381_04_M_XXEN/11.2020
Connection
Meter Slave ID
Baud rate
Parity
Data Bit
Stop Bit
1
9600
N (none) (except Saia) -> even
8
1
Additional Modbus meters can be included in future software updates upon customer request. Refer to the
Manufacturer
tab on the web server for a list of supported Modbus meters.
The Modbus meter interface is terminated with a terminating resistor of 120 Ω.
4.3.15 Gateway variants with modem
The charge controller supports 4G mobile networks. A 4G modem is integrated into the device. It uses a wire-
less module, which supports the following European frequency bands:
• LTE FDD: 800 MHz band 20, 900 MHz band 8, 1800 MHz band 3, 2100 MHz band 1 and 2600 MHz
band 7
• GSM: 900 MHz band 8 and 1800 MHz band 3
• WCDMA: 850 MHz band 5, 900 MHz band 8, and 2100 MHz band 1
• The charge controller can be operated as an "always-on system" when connected to a mobile net-
work.
• Connection is only possible when a SIM card is inserted in the SIM card slot located on the charge
controller front panel.
• The SIM card can have a PIN number which can be configured via the
Settings
tab.
• The APN settings for the SIM card can also be configured via the
Settings
tab.
I
C
aution
!
Damage to the SIM card slot by nano SIM cards!
The use of nano SIM cards with a SIM card ad-
apter may damage the SIM card reader. Therefore, it is recommended to use only micro SIM cards.
i
The SIM card can be removed via push-push.
Use in the EU
The use of device variants with an integrated 4G modem is only possible in member states of the European
Union.
i
If 4G mobile networks are not supported, GSM mobile networks may also be used.
• B-Control EM300-LR/EM300-LR (TCP)
• Carlo Gavazzi EM200/EM340
• Eastron SDM120/SDM220/ SDM630 series
• Finder
• Garo EM270/GNM1D/GNM3D/GNM3T/
GM3T
• IME CE4DMID31
4.3.14 Connectivity with Modbus meters
The use of a meter is not mandatory. It is necessary if measured values are required during normal operation.
The meter is connected to the Modbus meter interface (terminal B) of the charge controller. Various Modbus
meters are currently supported, including:
• ABB B23 series
• inepro PRO1/PRO2/PRO380
• NZR EcoCount S85
• Optec
• Phoenix Contact EEM-MB371 (TCP)
• Saia ALE3
• Siemens 7KT1666/7KM2200 (TCP)