CC613_D00381_04_M_XXEN/11.2020 21
CC613 charge controller
The Operator tab of the charging system control interface can be accessed via the URL http://192.168.123.123/
operator. To access this tab, user name and password are required:
• User name: operator
• Password: yellow_zone
The
Manufacturer
tab of the charging system control interface can be accessed via the URL
http://192.168.123.123/manufacturer. To access this tab, user name and password are required:
• User name: manufacturer
• Password: orange_zone
i
The default passwords should be changed to prevent unauthorised access.
The manufacturer can also change the user passwords and parameters via the Operator tab.
The URL for the Manufacturer tab should not be shared with the operator.
Basic settings can be made via the
Settings
tab:
• OCPP Mode (e.g. OCPP-B 1.5, OCPP-J 1.6)
• SOAP OCPP URL from the backend (i.e. the HTTP URL of the OCPP backend system)
• Websockets JSON OCPP URL of the Backend - Only applicable if
OCPP-J 1.6 mode has been selected.
The
Documentation
tab contains:
• Information on OCPP status display error messages (e.g. codes, activation and resolution messages,
instructions and corrective measures)
• OCCP configuration key for OCPP 1.5 and 1.6 (e.g. key name and description)
Application of changed parameters
Parameter changes are not necessarily applied after submission. To submit all changed parameters, click the
"Save & Restart" button at the bottom of the tab. A message indicating a necessary restart may appear.
I
a
utomatiC
reboot of the charge controller!
In order to ensure perfect functionality, the charge controller
carries out a regular system reboot. If no SIM card is inserted or the configuration does not yet match the
SIM card, a system reboot can be easily mistaken for a malfunction.
i
After the web configuration interface has been accessed or while a vehicle is connected, the charging point
will suppress system reboots for at least 2 minutes to allow all parameters to be configured.
5.1.2 Remote configuration of parameters
The charging system or rather the charge controller enables the configuration of many parameters using the
OCPP GetConfiguration and ChangeConfiguration commands. With these commands, locally configured com-
munication parameters can be changed. An exception are the SIM parameters, which require local interven-
tion when changing the SIM card.