5. Disconnect the supply hose from the hose
connector. Hold the two ends of the hose up
so shortening does not drip out. Hang hose
vertically over a pan so the shortening will
drip into the pan.
6. Attach the rinsing hose securely to the hose
connector. (See Figure 1-13.)
Figure 1-13. Rinsing Hose.
7. Position the EZ Melt so the filter is directly
under the drain in the fryer kettle.
8. Reach under the table and slowly open the
fryer’s drain valve.
9. Move the HEAT and PUMP switches of the
EZ Melt to the ON position.
10. Hold the insulated handle of the hose.
Direct the nozzle into the fryer kettle. Press
the foot pedal and rinse the kettle with
shortening. Do not let shortening splash out
of the kettle!
WARNING
To avoid burning yourself, never hold or
touch the metal portion of the nozzle while
the machine is in use. Wear protective
gloves.
WARNING
Thoroughly clean and dry the floor if
shortening, water, or other materials are
spilled. Materials spilled on the floor may
cause serious injury and loss of life.
11. After you have rinsed all the loose particles
out of the fryer kettle, release the foot pedal.
12. After the shortening has drained out of the
fryer kettle and through the EZ Melt filter,
close the drain valve.
13. Turn the EZ Melt off. Make sure that both
the HEAT and PUMP switches are in the
OFF position.
14. Disconnect the rinsing hose assembly. Hold
the two ends of the hose up so shortening
does not drip out. Hang the hose vertically
over a pan so shortening will drip into the
pan.
15. Bring the supply hose back to the EZ Melt,
holding the two ends of the hose up so
shortening does not drip out.
16. Securely attach the supply hose to the hose
connector. Make sure the outlet nozzle is
securely mounted to the fryer, with the
opening inside the kettle.
17. Move the HEAT and PUMP switches to the
ON position. Press the foot pedal to supply
filtered shortening to the fryer.
18. Before you filter shortening again, empty the
EZ Melt filter. Follow these steps: