3.

 

Product overview 

3.1.

 

 

3.2.

 

Module variants 

 

Part number  

Description 

I/O-connection 

Design 

LioN-Link BusHead 

 

 

 

0940 ESL 601  

BusHead  

PROFINET IO 

LioN-Link modules universal I/O digital 
0942 UEM 600  

8 In/Out universal  

4xM12  

0942 UEM 650  

8 In/Out universal  

8xM8  

0942 UEM 700  

16 In/Out universal  

8xM12  

0942 UEM 780  

16 In/Out universal  

Multipole interface  

LioN-Link modules input I digital 
0942 UEM 601  

8 In  

4xM12  

0942 UEM 651  

8 In  

8xM8  

0942 UEM 701  

16 In  

8xM12  

LioN-Link modules input I analogue 
0942 UEM 630  

I/O-module 4A I (0)4–20mA  

4xM12  

0942 UEM 631  

I/O-module 4A I 0–10V  

4xM12  

LioN-Link modules output O digital 
0942 UEM 602 

4 Out 

4xM12 

0942 UEM 612 

4 Out (for safety related 
applications) 

4xM12 

0942 UEM 782  

16 Out  

Multipole interface  

LioN-Link special modules 
0942 UEM 620 

IO-Link master 

4xM12 

0942 UEM 783 

Motion drive control 

8xM12 

 
 

3.3.

 

Accessories 

 

Part number 

Description 

PROFINET 
0985 342 100/… M 

Connecting cable for PROFINET, double ended with M12-plug, 
straight, 4-pole, D-coded 

0985 342 102/… M 

Connecting cable for PROFINET, single ended with M12-plug, 
straight, 4-pole, D-coded 

0985 342 104/… M 

Connecting cable for PROFINET, double ended with M12-plug, 
straight, 4-pole, D-coded and RJ45-plug, straight 

LioN-Link lines 
0935 253 103/… M 

Connecting cable for LioN-Link line, double ended, with M12-plug, 
straight, 5-pole, A-coded and M12-socket, straight, 5-pole, A-coded 

0935 253 104/… M 

Connecting cable for LioN-Link line, single ended, with M12-plug, 
straight, 5-pole, A-coded 

0935 253 105/… M 

Connecting cable for LioN-Link line, single ended, with M12-socket, 
straight, 5-pole, A-coded 

0935 253 106/… M 

Connecting cable for LioN-Link line, single ended, with M12-socket, 
angled, 5-pole, A-coded 

0935 253 107/… M 

Connecting cable for LioN-Link line, single ended, with M12-plug, 
angled, 5-pole, A-coded 

Содержание Lumberg Automation 0970 ESL 601

Страница 1: ...Technical Manual 0940 ESL 601...

Страница 2: ...pole D coded 12 5 1 2 Power supply connector for the BusHead M12 plug 5 pole 12 5 1 3 Link system connector M12 socket 5 pole 13 5 2 Intermediate power supply feed on LioN Link I O modules 14 5 2 1 T...

Страница 3: ...7 3 The monitoring page Monitoring 25 8 Firmware update 26 9 Alarm and error messages of the BusHead 27 9 1 Evaluation of alarms in STEP7 27 9 1 Reaction of the BusHead to a module breakdown pull ala...

Страница 4: ...s please do not hesitate to contact us We will be glad to be at your disposal at any time Belden Deutschland GmbH Lumberg Automation Im Gewerbepark 2 58579 Schalksmuehle Germany Tel 49 0 23 55 5044 00...

Страница 5: ...ferences in the residential area In this case the operator can be required to accomplish appropriate measures The proper and safe function of the product requires an appropriate transport storage inst...

Страница 6: ...ledge of the relevant standards have the same level of knowledge as after a technical education due to an activity in a comparable area for several years Modifications to the hard and software of our...

Страница 7: ...s is arbitrary The permissible overall length for each line may not be exceeded however Using the maximum expansion of the system an additional feed of the power supply for the system and sensors is p...

Страница 8: ...pole interface M LioN Link special modules 0942 UEM 620 IO Link master 4xM12 S 0942 UEM 783 Motion drive control 8xM12 M 3 3 Accessories Part number Description PROFINET 0985 342 100 M Connecting cabl...

Страница 9: ...ocket straight 5 pole contacts 1 3 connected A coded Field attachables 0986 EMC 102 Field attachable M12 plug for PROFINET cable straight 4 pole D coded with spring type terminals RSC 5 9 Field attach...

Страница 10: ...Technical Manual LioN Link PROFINET Subject to change without notice Version 1 2 August 2014 Page 10 of 30 4 Mounting 4 1 Outer dimensions...

Страница 11: ...g a flat washer according to DIN 125 has to be used Important note For the derivation of interference currents and or for the EMC stability the module provides a metal grounding sheet It is necessary...

Страница 12: ...lines 24 V DC to the data lines 5 1 2 Power supply connector for the BusHead M12 plug 5 pole Colour code of the connector grey Connector Pin Signal Function PROFINET ports P1 P2 1 TD Transmit Data 2 R...

Страница 13: ...in 4 Data Pin 5 Also the reverse connection of the power supply lines can lead to the destruction of the module Important note With long cable lengths an additional power supply feed is recommended se...

Страница 14: ...ctronics and sensors of the I O modules can be necessary If the power supply for the I O modules is not sufficient they deliver a diagnostics message The warning threshold for the diagnostics is appro...

Страница 15: ...ink line a calculation table as a Microsoft Excel sheet is available under http www beldensolutions com en Service Downloadcenter Software_Lumberg index phtml The table determines the voltage drop on...

Страница 16: ...g index phtml On request the GSDML file is also mailed by the support team The name of the file is as follows GSDML v2 2 Lumberg Automation LioN Link yyyymmdd xml in which yyyymmdd expresses the relea...

Страница 17: ...SL601 in the hardware catalogue Move the system to the PROFINET line of the control unit Insert now the I O modules of the LioN link system connected to the BusHead into the configuration Locate the I...

Страница 18: ...g and choose the menu item Edit Object Properties In the opening dialogue window you can change the device name Check whether the displayed IP address is correct and control unit and BusHead are locat...

Страница 19: ...ps determined by the IO Devices The LioN Link PROFINET BusHead supports the function of device exchange without removable media PG The topology of the network has to be configured for the use of the f...

Страница 20: ...Technical Manual LioN Link PROFINET Subject to change without notice Version 1 2 August 2014 Page 20 of 30...

Страница 21: ...missioning it is recommended to leave the parameter Interchanged Modules on the setting ACCEPT default setting In this mode it is possible to find the optimal installation and the most favourable wiri...

Страница 22: ...box Prioritized Start up in the window Properties Interface X1 should not be selected 6 4 6 Resetting the BusHead to factory settings In STEP7 resetting the BusHead to factory settings is carried out...

Страница 23: ...IP address According to the PROFINET standard all PROFINET IO devices are delivered with IP address 0 0 0 0 This means a free IP address deviating from the factory settings has to be assigned to the...

Страница 24: ...nfiguration page Configuration With the selection of the menu item Configuration on the left side of the homepage you are requested to enter a user name and a password Enter Admin as the user name and...

Страница 25: ...is also possible on this side The procedure is described in one of the following chapters of this manual and should be absolutely observed 7 3 The monitoring page Monitoring The page Monitoring gives...

Страница 26: ...s 0940ESL601_ERTEC bin The file names may not be changed 6 By clicking on the button Apply the firmware file is transferred to the BusHead Due to the size of the firmware for the ERTEC chip this proce...

Страница 27: ...iled information about the fault can be obtained in the fault OB by calling the SFB 54 RALRM Receive additional alarm information The SFB 54 therefore has to be called in every fault OB If the called...

Страница 28: ...xF Number of module with diagnostics Error code 0x00 Reserved 0x01 Short circuit 0x02 Low voltage 0x03 Overvoltage 0x04 Overload 0x05 Over temperature 0x06 Broken wire 0x07 Upper limit value exceeded...

Страница 29: ...ASE TX supported Manufacturer code Vendor ID 0016AH Device code Device ID 0302H Supported Ethernet protocols Ping ARP LLDP SNMP Network diagnostics DCP HTTP TCP IP Switch functionality integrated IRT...

Страница 30: ...th I O modules red Incorrect configuration modules permuted red green alternating flashing Restart of line 1 and or line 2 off Line 1 and or line 2 not used no I O module connected P1 Lnk Act P2 Lnk A...

Отзывы: