7.8
EMC and immunity
EMC interference emission
Standard applications
Railway applications (trackside)
EN 55032
Class A
Fulfilled
Fulfilled
FCC 47 CFR Part 15
Class A
Fulfilled
Fulfilled
EN 61000-6-4
Fulfilled
Fulfilled
EMC interference immunity
Standard applications
a
a. According to EN 61000-6-2.
Railway applications (trackside)
b
b. According to EN 50121-4.
Electrostatic discharge
EN 61000-4-2
Contact discharge
±4 kV
±6 kV
EN 61000-4-2
Air discharge
±8 kV
±8 kV
Electromagnetic field
EN 61000-4-3
80 MHz ... 3000 MHz
max. 10 V/m
max. 20 V/m
Fast transients (burst)
EN 61000-4-4
Supply voltage connection
±2 kV
±2 kV
EN 61000-4-4
Data line
±4 kV
±2 kV
Voltage surges - AC supply connection
EN 61000-4-5
line/ground
±2 kV
±2 kV
EN 61000-4-5
line/line
±1 kV
±1 kV
Voltage surges - data line
EN 61000-4-5
line/ground
±1 kV
±2 kV
Conducted disturbances
EN 61000-4-6
150 kHz ... 80 MHz
10 V
10 V
Immunity
Standard applications
Railway applications (trackside)
IEC 60068-2-6, test Fc
Vibration
5 Hz ... 8.4 Hz with 0.14 in (3.5 mm) amplitude —
8.4 Hz ... 150 Hz with 1 g
—
IEC 60068-2-27, test Ea
Shock
15 g at 11 ms
—