1.6.2
PSU module status
Figure 12: PSU module status: Location of the display elements on the device (rear
side of the device)
LED Display
Color Activity
Meaning
PWR Supply
voltage
—
none
At least one of the following cases applies:
PSU module is not plugged in.
There is no external supply voltage
or
it is too low.
No connection between PSU module
and basic device.
PSU module not operational.
green lights up
At least one of the following cases applies:
PSU module is plugged in.
Valid supply voltage connected.
red
flashes 1 time a
period
At least one of the following cases applies:
Supply voltage is too low
Supply voltage too high
PSU module fan failed
Overheating warning
green/
red
flashing alternately
Overload current protection mode
The PSU leaves the overload current
protection mode when the supply voltage
drops back into the permitted range.
See “Supply voltage” on page 70.