Installation DRAGON MACH Family
Release 04 02/2021
33
1.6
Display elements
After the supply voltage is set up, the Software starts and initializes the
device. Afterwards, the device performs a self-test. During this process,
various LEDs light up.
1.6.1
Device state
These LEDs provide information about conditions which affect the operation
of the whole device.
Figure 10: Device status: Location of the display elements on the device (front side
of the device)
LED Display
Color Activity
Meaning
STAT Device Status —
none
Device is starting and/or is not ready for
operation.
green lights up
Device is ready for operation.
Characteristics can be configured
red
lights up
Device is ready for operation.
Device has detected at least one error in
the monitoring results
flashes 1 time a
period
The boot parameters used when the
device has been started differ from the
boot parameters saved.
Start the device again.
flashes 4 times a
period
Device has detected a multiple IP address
ACA Storage
medium
ACA22
ACA31
—
none
ACA storage medium not connected
green lights up
ACA storage medium connected
flashes 3 times a
period
Device writes to/reads from the storage
medium
yellow lights up
ACA storage medium inoperative
FAN
ACA RM
P
P1
P2
STAT