Installation DRAGON MACH Family
Release 04 02/2021
61
3
Making basic settings
Note:
2 or more devices configured with the same IP address can cause
unpredictable operation of your network.
Install and maintain a process that assigns a unique IP address to every
device in the network.
The IP parameters must be entered when the device is installed for the first
time. The device provides the following options for configuring the IP
addresses:
V.24 interface (Command Line Interface)
BOOTP
DHCP
DHCP Option 82
AutoConfiguration Adapter
Input via the HiView or Industrial HiVision application. You find further
information about the applications HiView or Industrial HiVision on the
Internet at the Hirschmann product pages:
HiView
http://www.hirschmann.com/en/QR/INET-HiView
Industrial HiVision
http://www.hirschmann.com/en/QR/INET-Industrial-HiVision
Default settings
IP address: The device looks for the IP address using DHCP
Password for management:
Login: user; password: public (read only)
Login: admin; password: private (read and write)
Parameters that can be set via the management are set to pre-defined
values in accordance with the MIB
V.24 data rate: 9600 Baud
Ring redundancy: disabled
Ethernet ports: link status is not evaluated (signal contact)
Basic device:
Optical 10 Gbit/s ports: 10 Gbit/s full duplex
Autonegotiation deactivated.
Media module D4K-12TP-RJ45:
10/100/1000 Mbit/s ports: 10/100/1000 Mbit/s full duplex
Autonegotiation activated.
Media module D4K-12SFP:
Optical 100/1000 Mbit/s ports: 100/1000 Mbit/s full duplex
Autonegotiation exclusively activated for 1000 Mbit/s.
Out-of-band management port:
Default IP address: 192.168.1.1 / 255.255.255.0
Содержание Hirschmann DRAGON MACH Series
Страница 90: ......