22
Installation SPIDER II 16TX
Release 02 12/2014
5
Technical data
General technical data
Dimensions
W × H × D
See “Dimension drawings” on page 23.
Weight
25.75 oz (730 g)
Power supply
2 voltage inputs for redundant power supply
Safety extra-low voltage (SELV), redundant inputs disconnected
Relevant for North America: Class 2
Rated voltage range DC
24 V
Voltage range DC incl. maximum
tolerances
18 V ... 32 V
Connection type
5 pin, pluggable terminal block
for redundant power supply
Current consumption at 24 V DC SPIDER II 16TX EEC
0.41 A
SPIDER II 16TX/2DS-S EEC
0.45 A
Overload current protection at
input
Non-replaceable fuse
Back-up fuse per voltage input
a
a. As an alternative to the back-up fuse is possible:
Voltage supply according to Class 2 or EN 60950-1 Limited Power Source
4 A, slow blow
Peak inrush current
1.3 A
Potential differ-
ence between
incoming voltage
and housing
Potential difference from
incoming v24 V DC
+32 V DC
Potential difference from
incoming voltage, ground
−
32 V DC
Climatic condi-
tions during opera-
tion
Ambient air temperature
b
b. Temperature of the ambient air at a distance of 2 inches (5 cm) from the device
−
40 °F ... +158 °F (
−
40 °C ...
+70 °C)
Humidity
10 % ... 95 %
(non-condensing)
Air pressure
minimum 700 hPa (+9842 ft;
+3000 m)
Climatic condi-
tions during
storage
Ambient air temperature
c
c. Temperature of the ambient air at a distance of 2 inches (5 cm) from the device
−
40 °F ... +185 °F (
−
40 °C ... +85 °C)
Humidity
10 % ... 95 %
(non-condensing)
Air pressure
minimum 700 hPa (+9842 ft;
+3000 m)
Pollution degree
2
Protection classes Laser protection
Class 1 in compliance with IEC
60825-1
Degree of protection
IP 30
Содержание HIRSCHMANN 70914569
Страница 4: ...4 Installation SPIDER II 16TX Release 02 12 2014 ...
Страница 28: ...28 Installation SPIDER II 16TX Release 02 12 2014 ...
Страница 30: ......