6
Installation SPIDER II 16TX
Release 02 12/2014
Supply voltage
The supply voltage is electrically isolated from the housing.
Ground the device before connecting any other cables.
Connect only a supply voltage that corresponds to the type plate of
your device.
Every
time you connect the electrical conductors, make sure that the
following requirements are met:
The voltage supply conforms to overvoltage category I.
The power supply has an easily accessible disconnecting device
(e.g., a switch or a plug). This disconnecting device is clearly iden-
tified. So in the case of an emergency, it is clear which discon-
necting device belongs to which power supply cable.
The electrical wires are voltage-free.
Relevant for North America:
The power supply is Class 2 compliant.
The supply voltage inputs are designed for operation with safety
extra-low voltage. Connect only SELV circuits with voltage restric-
tions in line with IEC/EN 60950-1 to the supply voltage connec-
tions.
A fuse suitable for DC voltage is located in the plus conductor of the
power supply.
Regarding the properties of this fuse:
The wire diameter of the power supply cable is at least 1 mm²
(North America: AWG16) on the supply voltage input.
The power supply cables used are permitted for the temperature
range required by the application case.
Relevant for North America: For use in Class 2 circuits
Use copper wire/conductors of class 1 60/75 °C or 75 °C or 90 °C
exclusively.
Installation site requirements
Verify that there is at least 4 in (10 cm) of space above and below the
device.
Verify that there is at least 0.8 in (2 cm) of space on the right and left
sides of the device.
Only install the device in “operating sites with restricted access” based
on EN 60950-1.